Accepted Materials - Grade-level Waterproofing

Jump to: navigation, search

Accepted Materials - Grade-level Waterproofing


To view materials in any section listed below, click on the EXPAND button located at the right hand side of this page

1 Vapour Retarders

The RCABC does not specify Vapour Retarders, as they are not included in the RoofStar Guarantee Program. See manufacturer specifications where Vapour Retarders are required, and refer to proprietary products and installation instructions. This cross-reference is listed for information only.

2 Deck Overlay Boards

Two layers of gypsum board shall be installed over steel decks as an acceptable substrate for adhered waterproofing membranes when cast in place concrete topping is not present. The first layer of gypsum or cement board shall be either be fully mechanically fastened to the deck or adhered to the deck with manufacturer's approved compatible polyurethane adhesive. The second board layer must be adhered with a compatible manufacturer's approved polyurethane adhesive.
Expand
See the list below for materials acceptable for application on steel decks when specifying a RoofStar Waterproofing Guarantee. Note that only overlay boards measuring 12.7 mm (1/2") or more in thickness are acceptable for use in a RoofStar Waterproofing Guarantee. For more on this, see Gypsum Boards on Steel Decks under the RoofStar Guarantee Standards for Waterproofing:

3 Membrane Systems

RGC specifically accepted waterproofing membrane systems listed in the Accepted Materials of this Manual include the following:
  • Two Ply SBS Modified Bituminous Membrane Systems
  • Butyl Elastomeric Single Ply Membrane Systems (NOTE: Currently, there are no butyl membranes accepted for use in the RoofStar Guarantee Program)
  • Poly Vinyl Chloride (PVC) Plastomeric Single Ply Membrane Systems
  • Hot Fluid - Applied, Rubberized Asphalt Systems.
Only waterproofing membrane systems that are fully adhered and have an accepted protection layer installed above the membrane (protected) qualifies for coverage under the RoofStar Guarantee Program.
All waterproofing system accessory components must be supplied or be accepted for use by the membrane manufacturer.
Expand
Modified Bituminous (SBS) Membrane Systems
Expand
Thermoset (PVC) Membrane Systems
Expand
Hot Fluid-Applied, Rubberized Asphalt Membrane Systems

4 Membrane Protection Boards

Expand
A RoofStar-accepted membrane protection layer (asphalt core board, cap sheet or protection mat), must be installed by the waterproofing contractor, and be compatible with waterproofing membrane. The protection layer shall be installed and secured, as soon as possible, upon completion of waterproofing membrane installation. Construction traffic, by other than waterproofing trade and membrane moisture monitor technicians, is not permitted until the membrane protection layer is completely installed and secured.

5 Insulation

Expand
Extruded expanded polystyrene (Type 4), conforming to CAN/ULC-S701 (latest edition) with a compressive strength of 240 kPa (35psi) is the only commercially produced insulation suitable for use over waterproofing and protected membrane roofing systems. Extruded expanded polystyrene is available in a 600mm x 1200mm (2'x4') board size, has an aged R value of 5.0 per inch (RSI 0.87) and ranges in thickness' from 25mm (1") to 100mm (4").

6 Membrane Moisture Surveys & Monitoring Sensor Grids

Expand
A membrane moisture scan survey and report that confirms the water tight integrity of waterproofing systems is a mandatory requirement of the RoofStar Guarantee Program for all waterproofing systems, prior to installation of overburdens or wearing courses. Membrane moisture survey scans must be performed by an independent moisture detection company, whose moisture detection system has been reviewed by the RCABC Technical Committee and deemed to be suitable for inclusion in the RoofStar Guarantee Program (Waterproofing). In addition, moisture monitoring sensor grids (conductance scanning grid) are mandatory and shall be installed on the top surface of all waterproofing membrane systems designed with inaccessible overburdens and wearing courses. The exceptions that do not require moisture monitoring sensor grids are pavers on pedestals and gravel ballast to a maximum 100mm (4") thick . Moisture monitoring sensor grids shall be installed prior to installation of overburdens or wearing courses and may be placed over protection boards or SBS membranes that have been set in hot fluid-applied modified asphalt.
Note:
Flood Testing is not a recommended practice but is at the discretion of the design authority or owner. If flood testing is required to water test waterproofing membranes, testing shall be conducted prior to installation of insulation and overburdens and be performed to ASTM D5957 - 98.
Expand

7 Accessories




Waterproofing Plazas, Promenades and Terraces

Accepted Materials

Special Applications