Search results

Jump to: navigation, search

Search results

Page title matches

Page text matches

  • ...ally two different things'''''). The binder provides the membrane with its waterproofing capability and may impart the following properties: Bituminous and modified bituminous flexible membrane systems are composite sheet membranes which are thermoplastic in nature but display
    0 members (0 subcategories, 0 files) - 16:30, 23 June 2015
  • ...formation page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Divisio Roofing systems are often specified according to the &#8220;Class&#8221; of roof required.
    5 KB (808 words) - 16:06, 9 September 2021
  • ;Accepted for application in: Roof Waterproofing Systems ...heet membrane that is factory-laminated to a high-density Polyisocyanurate insulation support panel (SOPRA-ISO PLUS HD). The panel may be installed with hot bit
    2 KB (326 words) - 17:20, 16 June 2023
  • ...odified bituminous “binder”. The binder provides the membrane with its waterproofing capability and may impart the following properties: Bituminous and modified bituminous flexible membrane systems are composite sheet membranes which are thermoplastic in nature but display
    22 KB (3,281 words) - 21:46, 17 July 2017
  • ...roofing Systems (roofs)(high-density insulation overlay)<br>Water-shedding Systems (ASM and Asphalt Shingles) :*is a rigid roof insulation boards comprised of a high-density closed cell polyisocyanurate fo
    1 KB (196 words) - 15:40, 27 October 2020
  • ...roofing Systems (roofs)(high-density insulation overlay)<br>Water-shedding Systems (ASM and Asphalt Shingles) :*is a rigid roof insulation boards comprised of a high-density closed cell polyisocyanurate fo
    1 KB (196 words) - 15:42, 27 October 2020
  • :There are four principal waterproofing assemblies used on roofs; the choice of system may be influenced by the way ::'''''Uninsulated Systems''''' - typically insulated below the ''roof deck''.
    30 KB (4,336 words) - 21:13, 18 August 2021
  • <big><big>'''Waterproofing Roofs'''</big></big> ====Insulation====
    3 KB (432 words) - 21:52, 28 March 2024
  • ..., TPO, PVC) single ply membranes used for Landscaped and Vegetated roofing systems shall be fully adhered and a minimum thickness of 1.5mm (0.060"). || 2018-J ...tion of, a roof or waterproofing membrane assembly. This excludes thermal insulation but includes, and is not limited to, || 2018-January-25 }}
    21 KB (2,722 words) - 14:55, 25 September 2017
  • ..., TPO, PVC) single ply membranes used for Landscaped and Vegetated roofing systems shall be fully adhered and a minimum thickness of 1.5mm (0.060"). || 2018-J {{hilite | For roof membrane systems insulated above the membrane (Protected Membrane Roof assemblies), refer to
    21 KB (2,856 words) - 22:57, 9 November 2018
  • Only RoofStar-accepted insulation materials, specifically listed by membrane manufacturers in this Manual as ...be installed under two (2) offset / staggered layers of RoofStar-accepted insulation overlay boards.
    14 KB (2,160 words) - 15:21, 29 September 2016
  • ...ree of "humps" or depressions. These can counteract any sloped insulation systems installed by the roofing contractor and cause ponding. On new construction ...vel in the roof deck are less than the percentage of slope provided by the insulation.</span> <span class="recommended">A minimum slope of 1:50 (1/4" in 12") is
    20 KB (3,072 words) - 15:18, 15 January 2019
  • ...aterials used in the construction of ''waterproofing'' or ''water-shedding systems'' must be accepted by the '''''RGC'''''. Refer to other resources on this :<big>'''Acceptance Criteria for Roof Waterproofing System materials'''</big>
    22 KB (3,050 words) - 16:20, 12 December 2023
  • ...formation page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Divisio ...the latest in the evolution of bituminous roofing systems. However, some systems require that applicators use a propane-fuelled open flame torch to adhere t
    14 KB (2,333 words) - 16:39, 9 February 2022
  • ...bc.org/index.php?title=Low_Slope_Membrane_Roofs '''Low Slope Membrane Roof Systems''']. This cross-reference is listed for information only. .../index.php?title=Standard_for_SBS-Modified_Bitumen_Membrane_Systems#PART_7 Insulation]===
    6 KB (742 words) - 20:36, 27 July 2021
  • <big>Waterproofing Roof Systems: Thermosplastic Membranes</big><br> <big><big><big><big><big><big>Standard for PVC Membrane Roof Systems</big></big></big></big></big></big>
    416 KB (56,532 words) - 22:23, 5 April 2024
  • <big>Waterproofing Roof Systems: Thermoset Membranes</big><br> <big><big><big><big><big><big>Standard for EPDM Membrane Roof Systems</big></big></big></big></big></big>
    424 KB (57,418 words) - 22:20, 5 April 2024
  • <big>Waterproofing Roof Systems: Thermosplastic Membranes</big><br> <big><big><big><big><big><big>Standard for TPO Membrane Roof Systems</big></big></big></big></big></big>
    421 KB (57,062 words) - 22:20, 5 April 2024
  • <big>Waterproofing Roof Systems: Liquid Membranes</big><br> ...<big><big><big><big>Standard for Hot Fluid-applied Rubberized Asphalt Roof Systems</big></big></big></big></big></big>
    296 KB (41,811 words) - 22:23, 5 April 2024
  • <tab name="Materials for Waterproofing Roof Systems"> ::<big>[[Waterproofing Systems (Roofs): Hybrid Bituminous EPDM Membranes |Hybrid EPDM Membranes]]</big>
    13 KB (1,636 words) - 17:02, 5 January 2024
  • ...formation page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Divisio ...ree of "humps" or depressions. These can counteract any sloped insulation systems installed by the roofing contractor and cause ponding. On new construction
    20 KB (2,969 words) - 16:06, 9 September 2021
  • <span class="reference">When any portion of a waterproofing system is installed with heat, the work is classified as Hot Work. Some to ==Contractor Qualifications for Roof and Grade-level Waterproofing==
    11 KB (1,608 words) - 22:03, 3 May 2021
  • ...Systems''', '''Water-shedding Systems''', and '''Grade-level Waterproofing Systems'''. Explanatory notes may be incorporated at the end of each Standard. ...Waterproofing Roof Systems" is a Group; "Polymer-modified Bitumen Membrane Systems" is a System type). Each Standard published in the RPM is an arrangement o
    15 KB (2,132 words) - 19:02, 18 August 2023
  • [[File:Low-slope Roof Insulation.jpg|300 px]] ...formation page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Divisio
    23 KB (3,279 words) - 15:42, 9 September 2021
  • ...b> and shall be installed on the top surface of all waterproofing membrane systems designed with inaccessible overburdens and wearing courses. The exceptions ...terproofing membranes, testing shall be conducted prior to installation of insulation and overburdens and be performed to ASTM D5957 - 98.
    2 KB (249 words) - 22:45, 9 November 2016
  • <big><big><big><big><big>Insulation Joints and Overlays</big></big></big></big></big> ...formation page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Divisio
    4 KB (532 words) - 15:44, 9 September 2021
  • ...ish or a sanded finish. PERMA-BOARD is compatible with all asphalt roofing systems and is unaffected by moisture and will not rot. ...may be heat welded or hot mopped directly to PERMA-BOARD, creating a thick waterproofing layer. The asphalt board becomes an integral part of the roof membrane maki
    3 KB (361 words) - 22:21, 3 November 2016
  • ...formation page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Divisio ...materials due to thermal and moisture variations. Traditionally, the roof insulation and roofing are secured to the roof deck by means of mechanical fastening,
    7 KB (999 words) - 15:42, 9 September 2021
  • ...formation page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Divisio ...heat and reverting to more solid material as they cool. Their adhesive and waterproofing properties have been utilized in construction for hundreds of years. The mo
    15 KB (2,293 words) - 15:33, 9 September 2021
  • <big><big><big><big><big>Protected and Modified Protected Roof Systems</big></big></big></big></big> ...formation page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Divisio
    11 KB (1,624 words) - 16:21, 9 September 2021
  • ;(1) [[SBS Roof Systems Standard#PART_9|'''Base Membrane (field)''']]: See Tables '''9.1''' and ''' ...flashing must extend up the vertical plane, and above the ''Finished Roof/Waterproofing Surface'', at least 200 mm (8”), and must extend onto the roof field at l
    5 KB (661 words) - 17:37, 27 October 2023
  • ...ata is also included on flexible membrane (&#8220;non-conventional&#8221;) systems as applicable. * Insulation to replace any wet materials discovered in cuts
    75 KB (11,617 words) - 21:00, 3 September 2021
  • ...roofing materials and components, such as single-ply membranes, flashings, insulation boards, etc. Before adhesives are applied, their compatibility with other ...urement (for more on this subject, refer to Article 3.1.3.4. in any of the waterproofing roof Standards for sheet membrane roofs, published in Division B of the RPM
    76 KB (11,565 words) - 18:09, 26 January 2024
  • <u>Built-Up Roofing Systems Design Guide</u>. Rockville, MA: The Asphalt Roofing Manufacturers Associat <u>Design and Specification of Roofing Systems</u>. Englewood, CO: Roofing Industry Educational Institute, Seminar Manual.
    4 KB (548 words) - 14:32, 18 August 2023
  • === [[RoofStar Guarantee Standards for EPDM Membrane Systems#EPDMVAPOUR|Air and Vapour Control]] === ...bc.org/index.php?title=Low_Slope_Membrane_Roofs '''Low Slope Membrane Roof Systems''']. This cross-reference is listed for information only.
    5 KB (633 words) - 20:30, 26 July 2021
  • === [[RoofStar Guarantee Standards for TPO Membrane Systems#TPOVAPOUR|Air and Vapour Control]] === ...bc.org/index.php?title=Low_Slope_Membrane_Roofs '''Low Slope Membrane Roof Systems''']. This cross-reference is listed for information only.
    5 KB (614 words) - 20:30, 26 July 2021
  • ...sulation that is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes ...ilitating the flow of water infiltrated under the insulating boards to the waterproofing system's surface and drains.
    3 KB (353 words) - 17:41, 13 October 2016
  • ...sulation that is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes ...ilitating the flow of water infiltrated under the insulating boards to the waterproofing system's surface and drains.
    3 KB (353 words) - 17:42, 13 October 2016
  • ...sulation that is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes ...ilitating the flow of water infiltrated under the insulating boards to the waterproofing system's surface and drains.
    3 KB (353 words) - 17:42, 13 October 2016
  • ...sulation that is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes ...ilitating the flow of water infiltrated under the insulating boards to the waterproofing system's surface and drains.
    3 KB (353 words) - 17:42, 13 October 2016
  • ;Accepted for application in: Roof Waterproofing Systems ...density mineral wool (stone wool) support panel and on a polyisocyanurate insulation board (SOPRA-ISO).
    1 KB (201 words) - 22:05, 28 June 2021
  • ...cated from Part 3 of the ''Standard for SBS-modified Bitumen Membrane Roof Systems'', located in [[Division B | '''Division B: Standards''']], and is largely ...applies to all new roofs, and to both full and partial replacement ''roof systems''|| 2021-October-30 }}.
    55 KB (7,359 words) - 21:22, 3 October 2023
  • ;Accepted for application in: Roof Waterproofing Systems<br>Water-shedding Systems ...nts an improvement to the product; Resista was rated as a Type 1 "Polyiso" insulation (compressive strength: 138 kPa), while ISOGARD CG can now be classified as
    2 KB (298 words) - 21:03, 19 June 2023
  • ...pted for application in: All Roof Waterproofing Systems and Water-shedding Systems ...ximum thermal efficiency. Hunter Panels Polyisocyanurate '''H-Shield CG''' insulation is UL and FM approved as a system component in certain roofing assemblies.
    2 KB (220 words) - 18:51, 28 June 2021
  • ;Accepted for application in: Roof Waterproofing Systems ...ct Summary: Polyisocyanurate '''H-Shield CG''' is a high-density foam core insulation overlay board covered on both sides with a medium weight fiber-glass reinfo
    1 KB (170 words) - 18:55, 28 June 2021
  • ...rsion in water with the exception of protected and modified protected roof systems. ...ue to the elements and from mechanical damage. The metal flashing is not a waterproofing membrane, therefore the roofing membrane should be continuous under the met
    12 KB (1,696 words) - 22:01, 7 March 2018
  • <big><big><big><big><big>Carlisle SynTec Systems Canada</big></big></big></big></big><br> <big><big>'''Waterproofing Roofs'''</big></big>
    4 KB (472 words) - 16:22, 31 October 2023
  • ...rsion in water with the exception of protected and modified protected roof systems. ...ue to the elements and from mechanical damage. The metal flashing is not a waterproofing membrane, therefore the roofing membrane should be continuous under the met
    10 KB (1,482 words) - 22:00, 7 March 2018
  • ...ng to CAN / CGSB-51.20-M87, Type 4) is the only commercially produced roof insulation suitable for a PMRA, providing properties such as water resistance (i.e. re ...ne as well as on top. This may offer cost savings as only the top layer of insulation requires ballast and the bottom layer (mechanically-fastened or adhered) ne
    9 KB (1,317 words) - 14:38, 24 August 2017
  • <big><big>'''Waterproofing Roofs'''</big></big> <big><big>'''Waterproofing Roofs'''</big></big>
    3 KB (449 words) - 14:48, 8 June 2023
  • <big><big>'''Waterproofing Roofs'''</big></big> ====Insulation====
    8 KB (993 words) - 20:26, 20 March 2024
  • <big><big>'''Waterproofing Roofs'''</big></big> ====Insulation====
    3 KB (405 words) - 20:43, 8 June 2023
  • <big><big>'''Waterproofing Roofs'''</big></big> ====Insulation====
    11 KB (1,293 words) - 20:23, 20 March 2024
  • ==== [[Roof Deck Insulation]] ==== :'''Tapered Insulation'''
    2 KB (254 words) - 17:18, 6 June 2016
  • ==== [[Roof Deck Insulation]] ==== :'''Tapered Insulation'''
    2 KB (254 words) - 17:18, 6 June 2016
  • <big><big>'''Waterproofing Roofs'''</big></big> ====Insulation====
    6 KB (824 words) - 19:17, 1 February 2024
  • ...and specification writers designing or applying roofing and waterproofing systems, and describes the RoofStar Guarantee Standards, Guiding Principles and Rec :[[Insulation Joints and Overlay|Insulation Joints and Overlay Boards]]
    7 KB (990 words) - 20:54, 2 August 2016
  • <big><big><big><big><big>Standard for Grade-level Waterproofing Systems</big></big></big></big></big> =ABOUT WATERPROOFING=
    117 KB (13,071 words) - 18:36, 5 April 2024
  • ...shall be installed over steel decks as an acceptable substrate for adhered waterproofing membranes when cast in place concrete topping is not present. The first lay ...Guarantee Standards for Waterproofing|'''RoofStar Guarantee Standards for Waterproofing''']]:
    7 KB (968 words) - 20:34, 26 July 2021
  • ..., TPO, PVC) single ply membranes used for Landscaped and Vegetated roofing systems shall be fully adhered and a minimum thickness of 1.5mm (0.060"). ...oot intrusion barrier, and drainage layer. Tightly butt all protection and insulation boards, overlap all filter mat seams and seal all laps of roof intrusion ba
    7 KB (1,036 words) - 15:41, 20 July 2018
  • ...water with the exception of protected and modified protected waterproofing systems. || 2016-October-22 }} ...ue to the elements and from mechanical damage. The metal flashing is not a waterproofing membrane, therefore the roofing membrane should be continuous under the met
    9 KB (1,399 words) - 22:09, 21 October 2016
  • ;'''Manufacturer''': [https://www.carlislesyntec.com/ '''Carlisle Syntec Systems Canada'''] ;Accepted for application in: Roof Waterproofing Systems
    2 KB (262 words) - 18:30, 28 June 2021
  • ...woven polyethylene is compatible for the use of sprayed polyurethane foam insulation. The underface is covered with a silicone release paper or film. .... It is also used as masonry and through wall flashing membrane as well as waterproofing membrane at openings and transitions. SOPRASEAL STICK 1100 T can also be us
    2 KB (260 words) - 19:13, 28 November 2016
  • ...#8221; and &#8220;Teranap&#8221; series are Siplast&#8217;s major membrane systems, with a number of speciality membranes designed to extend their range of ap #* the waterproofing system
    22 KB (3,408 words) - 18:30, 9 November 2016
  • ...nd &#8220;Elastophene&#8221; membranes, and the High Performance Composite systems, all tough, flexible SBS polymer modified bitumen prefabricated sheets, app ...es, bonding adjacent sheets and flashing plies to form an integral roofing/waterproofing system.
    14 KB (2,024 words) - 18:30, 9 November 2016
  • ...ne torch or cold-process adhesives in all types of roofing / waterproofing systems. ...d 2-ply (or more) system on flat, curved or domed roofs over most types of insulation.
    8 KB (1,192 words) - 19:52, 7 November 2016
  • The main components of the roofing and waterproofing systems are the TORCHFLEX and MODIFLEX membranes: tough, flexible, SBS polymer modi ...nding the adjacent sheets and flashing plies to form an integral roofing / waterproofing system.
    11 KB (1,543 words) - 18:21, 9 November 2016
  • Product Group: <b>SBS MODIFIED BITUMINOUS WATERPROOFING MEMBRANES</b> The main components of the waterproofing systems are the TORCHFLEX and MODIFLEX membranes: tough, flexible, SBS polymer modi
    8 KB (1,205 words) - 18:26, 9 November 2016
  • The main components of the roofing and waterproofing systems are bitumen modified with SBS (Styrene Butadiene Styrene) and either fibreg # For use in &#8220;protected membrane&#8221; applications under insulation.
    12 KB (1,673 words) - 19:42, 7 November 2016
  • ...ed bitumen to produce roof membranes designed for use in a variety of roof systems. Firestone manufacturers a variety of membranes, each of which is designed ::* Waterproofing
    21 KB (3,147 words) - 19:39, 7 November 2016
  • <i>Product Group:</i> <b>BUILT-UP ROOFING SYSTEMS EXPOSED MEMBRANES, INSULATED </b> ...hot steep roofing asphalt; apply to any prepared roof substrate or roofing insulation suitable for hot applied roofing asphalt, or to a mechanically attached bas
    25 KB (3,685 words) - 16:52, 4 November 2016
  • Manufacturer: <b>CARLISLE SYNTEC SYSTEMS CANADA</b> ...c membrane is the key component used in Carlisle roofing and waterproofing systems. The membrane is applied in large sheets to reduce field seams. Exceptional
    30 KB (4,433 words) - 22:21, 7 November 2016
  • ...rane is the key component used in Johns Manville roofing and waterproofing systems. The membrane is applied in large sheets to reduce field seams. Exceptional ...fing Systems, Ballasted Roofing Systems; and Mechanically Fastened Roofing Systems.
    20 KB (3,027 words) - 23:04, 7 November 2016
  • :;''Extensive Vegetated Roof Systems'': sometimes referred to as "eco-roofs", 'low-profile green roofs," "roofto ...t is situated on top of, and covering all or a portion of, a constructed ''waterproofing system''. ''Overburden'' includes, without limitation,
    32 KB (4,724 words) - 17:43, 16 November 2021
  • <li>To qualify for a '''''RoofStar 15-year (Waterproofing Roofs) Guarantee''''', the following standards apply: ...enance || 2022-February-5 }} ([[Standard for SBS-Modified Bitumen Membrane Systems#Accessibility_for_Maintenance | 1.3.3]]).
    28 KB (3,908 words) - 15:24, 4 August 2021
  • The main component of the roofing and waterproofing systems is the Sarnafil Membrane, a tough flexible polyvinyl chloride (PVC) sheet, ...-laid roofing membrane under gravel ballast and in protected membrane roof systems.
    42 KB (6,360 words) - 18:54, 9 November 2016
  • Product Group: <b>POLYVINYL CHLORIDE WATERPROOFING MEMBRANES</b> The main component of the waterproofing systems is the Sarnafil Membrane, a tough flexible polyvinyl chloride (PVC) sheet,
    22 KB (3,157 words) - 18:55, 9 November 2016
  • ...s are mopped applied or mechanically fastened to the prepared substrate or insulation. ...oratories: Class A, B and C Flame Resistance, &#8220;Roofing Materials and Systems Directory&#8221;, 2001 Edition.
    36 KB (5,546 words) - 18:22, 8 November 2016
  • PROJECT NO. (OPTIONAL) Modified Bituminous Sheet Waterproofing ...tion for two ply SBS modified bituminous membranes in a protected membrane waterproofing system.
    23 KB (2,972 words) - 19:49, 9 November 2016
  • ...nts for polyvinyl chloride (PVC) waterproofing in protected membrane (PMR) systems. ::.2 RGC Guarantee Standards [E Waterproofing].
    18 KB (2,262 words) - 19:50, 9 November 2016
  • ...for Butyl (IIR) Sheet Membrane waterproofing in a protected membrane (PMR) systems. ::.2 RGC Guarantee Standards [E Waterproofing].
    19 KB (2,419 words) - 19:52, 9 November 2016
  • APPLIED RUBBERIZED ASPHALT WATERPROOFING ...lied rubberized asphalt (HARA) waterproofing in a protected membrane (PMR) systems.
    18 KB (2,332 words) - 19:53, 9 November 2016
  • <big>Guide Specification - Membrane Moisture Survey Systems</big> Refer to the following Membrane Moisture Survey Systems for the manufacturer's individual proprietary guide specifications when dev
    12 KB (1,634 words) - 22:57, 9 November 2016
  • <big>Guide Specification - Membrane Moisture Survey Systems</big> Refer to the following Membrane Moisture Survey Systems for the manufacturer's individual proprietary guide specifications when dev
    12 KB (1,693 words) - 22:58, 9 November 2016
  • ..., TPO, PVC) single ply membranes used for Landscaped and Vegetated roofing systems shall be fully adhered and a minimum thickness of 1.5mm (0.060"). || 2018-J {{hilite | For roof membrane systems insulated above the membrane (Protected Membrane Roof assemblies), refer to
    22 KB (3,002 words) - 14:56, 25 September 2017
  • ...ree of "humps" or depressions. These can counteract any sloped insulation systems installed by the roofing contractor and cause ponding. On new construction ...vel in the roof deck are less than the percentage of slope provided by the insulation.</span> <span class="recommended">A minimum slope of 1:50 (1/4" in 12") is
    21 KB (3,117 words) - 22:49, 10 November 2016
  • ...rsion in water with the exception of protected and modified protected roof systems. ...ue to the elements and from mechanical damage. The metal flashing is not a waterproofing membrane, therefore the roofing membrane should be continuous under the met
    10 KB (1,568 words) - 22:02, 7 March 2018
  • :'''<big>ARCHITECTURAL CONCEALED FASTENER METAL ROOFING SYSTEMS ONLY</big>''' ...metal panels may also be designed for use as structural (spanning member) systems, only their use as an architectural metal panel system (over solid deck) is
    95 KB (14,221 words) - 18:16, 19 September 2023
  • ...ng to CAN / CGSB-51.20-M87, Type 4) is the only commercially produced roof insulation suitable for a PMA, providing properties such as water resistance (i.e. res ...ng, the insulation is to be applied loose with a permeable fabric over the insulation.
    8 KB (1,153 words) - 18:04, 23 May 2017
  • :[[File:SBS Systems page thumb.JPG | link=http://rpm.rcabc.org/images/6/62/SBS_Systems_page_thu ...ems_(revised)<big>{{hilite | '''Standard for SBS-Modified Bitumen Membrane Systems'''</big> || 2020-October-21 }}]
    3 KB (424 words) - 13:52, 27 August 2021
  • === [[RoofStar Guarantee Standards for PVC Membrane Systems#PVCVAPOUR|Air and Vapour Control]] === ...bc.org/index.php?title=Low_Slope_Membrane_Roofs '''Low Slope Membrane Roof Systems''']. This cross-reference is listed for information only.
    5 KB (611 words) - 20:30, 26 July 2021
  • ...}} system''|| 2020-February-3 }}: {{hilite | means the top surface of a ''waterproofing system'' or ''water-shedding system'' that may include ballast or that supp ...slope, excludes water from a building and therefore waterproofs it. These systems are typically installed on slopes less than 1:4 (3” in 12”), on roofs o
    37 KB (5,263 words) - 18:02, 12 November 2021
  • ...(adapted from ''ASTM D1079-18 Standard Terminology Relating to Roofing and Waterproofing'')|| 2021-June-30 }}. ...r function – ''<u>waterproofing</u> systems'' or ''<u>water-shedding</u> systems''. Within each classification, slope is defined as follows:
    27 KB (3,843 words) - 16:12, 15 October 2021
  • ...}} system''|| 2020-February-3 }}: {{hilite | means the top surface of a ''waterproofing system'' or ''water-shedding system'' that may include ballast or that supp ...slope, excludes water from a building and therefore waterproofs it. These systems are typically installed on slopes less than 1:4 (3” in 12”), on roofs o
    38 KB (5,288 words) - 17:30, 22 November 2021
  • ...}} system''|| 2020-February-3 }}: {{hilite | means the top surface of a ''waterproofing system'' or ''water-shedding system'' that may include ballast or that supp ...slope, excludes water from a building and therefore waterproofs it. These systems are typically installed on slopes less than 1:4 (3” in 12”), on roofs o
    35 KB (4,946 words) - 18:01, 12 November 2021
  • ...}} System''|| 2020-February-3 }}: {{hilite | means the top surface of a ''Waterproofing System'' or ''Water-shedding System'' that may include ballast or ''Overbur :;''Project'': means the designed or constructed ''Waterproofing System'' or ''Water-shedding System''.
    40 KB (5,809 words) - 18:25, 4 February 2021
  • ...ard test method for the dynamic wind uplift resistance of membrane-roofing systems'' (latest edition). ...any material, structure or item of equipment that is placed on top of a ''waterproofing system''. Gravel or pavers constitute ''overburden'' when they do not funct
    54 KB (7,505 words) - 18:08, 12 November 2021
  • <big><big><big>by Carlisle SynTec Systems Canada</big></big></big><br> ;Accepted for application in: Roof Waterproofing Systems
    3 KB (361 words) - 18:56, 31 October 2023
  • <big><big><big>by Carlisle SynTec Systems Canada</big></big></big><br> ;Accepted for application in: Roof Waterproofing Systems
    3 KB (363 words) - 18:56, 31 October 2023
  • <big><big><big>by Carlisle SynTec Systems Canada</big></big></big><br> ;Accepted for application in: Roof Waterproofing Systems
    3 KB (365 words) - 18:57, 31 October 2023
  • <big><big><big><big><big>SecurShield RapidLock (RL) Polyiso Insulation</big></big></big></big></big><br> <big><big><big>by Carlisle SynTec Systems Canada</big></big></big><br>
    2 KB (317 words) - 18:51, 24 October 2023
  • <big><big><big><big><big>SecurShield RapidLock (RL) HD Polyiso Insulation</big></big></big></big></big><br> <big><big><big>by Carlisle SynTec Systems Canada</big></big></big><br>
    2 KB (318 words) - 18:50, 24 October 2023
  • ...(adapted from ''ASTM D1079-18 Standard Terminology Relating to Roofing and Waterproofing'')|| 2021-June-30 }}. ...r function – ''<u>waterproofing</u> systems'' or ''<u>water-shedding</u> systems''. Within each classification, slope is defined as follows:
    27 KB (3,807 words) - 16:12, 15 October 2021
  • ...thetic finish to the ''roof system''. ''Linear metal flashings'' are not a waterproofing component. Consequently, the roofing membrane should be continuous beneath ...metal flashings. RoofStar-accepted pre-engineered products are accepted as systems and therefore the requirements in this Part for metal gauge, profile, secur
    28 KB (4,147 words) - 19:33, 12 November 2021
  • ...Insulation overlay boards are installed in most ''Conventionally Insulated Systems'' to</span> <li><span class="reference">protect ''heat-sensitive insulation'' materials from damage by heat and flame</span>.
    10 KB (1,336 words) - 13:49, 14 April 2021
  • <big><big><big><big><big>Notes to Standard for Asphalt Shingle Roof Systems</big></big></big></big></big> :<big>'''A-1.1.3.1.'''</big> ('''Permitted Roof Systems''')
    27 KB (3,999 words) - 15:35, 14 November 2023
  • <big><big><big><big><big>Notes to Standard for EPDM Membrane Roof Systems</big></big></big></big></big> :<big>'''A-1.1.3.1.'''</big> ('''Permitted Roof Systems''')
    59 KB (8,538 words) - 18:07, 2 April 2024
  • This section pertains to the waterproofing of roof penetrations, curbs, sleepers, drains and any other "details", in o ...(see '''7.1.2.10'''). <span class="recommended">Sumps designed with sloped insulation are strongly recommended</span>.
    42 KB (6,354 words) - 15:16, 15 July 2020
  • ...mbrane Roof Systems'' or ''Modified Protected Membrane Systems''; in these systems, gravel ballast or pavers are used to secure the ''system'' materials again <li>a drainage layer beneath XPS insulation.
    14 KB (2,184 words) - 19:32, 12 November 2021
  • :;''Extensive Vegetated Roof Systems'': sometimes referred to as "eco-roofs", 'low-profile green roofs," "roofto ...t is situated on top of, and covering all or a portion of, a constructed ''waterproofing system''. ''Overburden'' includes, without limitation,
    31 KB (4,708 words) - 19:34, 12 November 2021
  • <big><big><big><big><big>Standard for Grade-level Waterproofing Systems</big></big></big></big></big> =ABOUT WATERPROOFING=
    117 KB (13,068 words) - 18:35, 5 April 2024
  • ...><big><big><big>Notes to Standard for Architectural Sheet Metal (ASM) Roof Systems</big></big></big></big></big> :<big>'''A-1.1.3.1.'''</big> ('''Permitted Roof Systems''')
    32 KB (4,655 words) - 13:53, 9 April 2024
  • ;Accepted use: Waterproofing Systems (roofs) ...ane support on low slope roofs. It can be installed on plywood or on rigid insulation.
    2 KB (240 words) - 17:26, 14 February 2020
  • ...ard test method for the dynamic wind uplift resistance of membrane-roofing systems'' (latest edition). ...any material, structure or item of equipment that is placed on top of a ''waterproofing system''. Gravel or pavers constitute ''overburden'' when they do not funct
    54 KB (7,486 words) - 18:09, 12 November 2021
  • <big><big>'''Waterproofing Roofs'''</big></big> ====Insulation====
    7 KB (897 words) - 18:41, 8 June 2023
  • ...}} system''|| 2020-February-3 }}: {{hilite | means the top surface of a ''waterproofing system'' or ''water-shedding system'' that may include ballast or that supp ...slope, excludes water from a building and therefore waterproofs it. These systems are typically installed on slopes less than 1:4 (3” in 12”), on roofs o
    35 KB (4,973 words) - 17:30, 22 November 2021
  • ...mbrane Roof Systems'' or ''Modified Protected Membrane Systems''; in these systems, gravel ballast or pavers are used to secure the ''system'' materials again ##a drainage layer beneath XPS insulation.
    14 KB (2,169 words) - 15:17, 23 February 2022
  • ...ard test method for the dynamic wind uplift resistance of membrane-roofing systems'' (latest edition). ...any material, structure or item of equipment that is placed on top of a ''waterproofing system''. Gravel or pavers constitute ''overburden'' when they do not funct
    55 KB (7,522 words) - 23:07, 8 March 2022
  • ...(adapted from ''ASTM D1079-18 Standard Terminology Relating to Roofing and Waterproofing'')|| 2021-June-30 }}. ...r function – ''<u>waterproofing</u> systems'' or ''<u>water-shedding</u> systems''. Within each classification, slope is defined as follows:
    25 KB (3,617 words) - 14:49, 23 December 2021
  • <big><big><big><big><big>Notes to Standard for TPO Membrane Roof Systems</big></big></big></big></big> :<big>'''A-1.1.3.1.'''</big> ('''Permitted Roof Systems''')
    57 KB (8,227 words) - 18:02, 2 April 2024
  • <big><big><big><big><big>Notes to Standard for PVC Membrane Roof Systems</big></big></big></big></big> :<big>'''A-1.1.3.1.'''</big> ('''Permitted Roof Systems''')
    57 KB (8,227 words) - 18:07, 2 April 2024
  • ...><big><big><big>Notes to Standard for Architectural Sheet Metal (ASM) Roof Systems</big></big></big></big></big> :<big>'''A-1.1.3.1.'''</big> ('''Permitted Roof Systems''')
    31 KB (4,535 words) - 15:47, 27 October 2023
  • <big><big><big><big><big>Notes to Standard for Asphalt Shingle Roof Systems</big></big></big></big></big> :<big>'''A-1.1.3.1.'''</big> ('''Permitted Roof Systems''')
    27 KB (3,996 words) - 15:35, 14 November 2023
  • ...(adapted from ''ASTM D1079-18 Standard Terminology Relating to Roofing and Waterproofing'')|| 2021-June-30 }}. ...r function – ''<u>waterproofing</u> systems'' or ''<u>water-shedding</u> systems''. Within each classification, slope is defined as follows:
    25 KB (3,582 words) - 14:49, 23 December 2021
  • ...ecified ''system'' and may be required or simply is prudent for additional waterproofing protection in certain circumstances</span>. <li>accepted concrete-topped XPS insulation panels.
    59 KB (6,024 words) - 17:30, 15 June 2022
  • :;''Extensive Vegetated Roof Systems'': sometimes referred to as "eco-roofs", 'low-profile green roofs," "roofto ...t is situated on top of, and covering all or a portion of, a constructed ''waterproofing system''. ''Overburden'' includes, without limitation,
    32 KB (4,724 words) - 17:44, 16 November 2021
  • ...mbrane Roof Systems'' or ''Modified Protected Membrane Systems''; in these systems, gravel ballast or pavers are used to secure the ''system'' materials again <li>a drainage layer beneath XPS insulation.
    14 KB (2,184 words) - 18:04, 15 November 2021
  • ...thetic finish to the ''roof system''. ''Linear metal flashings'' are not a waterproofing component. Consequently, the roofing membrane should be continuous beneath ...metal flashings. RoofStar-accepted pre-engineered products are accepted as systems and therefore the requirements in this Part for metal gauge, profile, secur
    28 KB (4,147 words) - 21:42, 27 April 2022
  • ...thetic finish to the ''roof system''. ''Linear metal flashings'' are not a waterproofing component. Consequently, the roofing membrane should be continuous beneath ...metal flashings. RoofStar-accepted pre-engineered products are accepted as systems and therefore the requirements in this Part for metal gauge, profile, secur
    28 KB (4,147 words) - 21:41, 27 April 2022
  • ...ority'' is responsible to specify {{hilite | the connections between the ''waterproofing'' or ''water-shedding system'' and ''walls'' or other building components, ...all finish must be installed at least 89 mm (3 ½”) above the ''finished waterproofing system''.
    48 KB (6,869 words) - 22:24, 9 December 2021
  • This section pertains to the waterproofing of roof penetrations, curbs, sleepers, drains and any other "details", in o ...021-October-30 }}</span> {{hilite | (relative to the top of the ''finished waterproofing system'') – the location of the ''drainage plane'' may affect the determi
    56 KB (8,120 words) - 20:44, 19 May 2022
  • This section pertains to the waterproofing of roof penetrations, curbs, sleepers, drains and any other "details", in o ...021-October-30 }}</span> {{hilite | (relative to the top of the ''finished waterproofing system'') – the location of the ''drainage plane'' may affect the determi
    45 KB (6,830 words) - 19:36, 11 March 2022
  • ...ority'' is responsible to specify {{hilite | the connections between the ''waterproofing'' or ''water-shedding system'' and ''walls'' or other building components, ...all finish must be installed at least 89 mm (3 ½”) above the ''finished waterproofing system''.
    36 KB (5,070 words) - 14:52, 17 November 2021
  • ...mbrane Roof Systems'' or ''Modified Protected Membrane Systems''; in these systems, gravel ballast or pavers are used to secure the ''system'' materials again ##a drainage layer beneath XPS insulation.
    14 KB (2,171 words) - 19:31, 12 November 2021
  • This section pertains to the waterproofing of roof penetrations, curbs, sleepers, drains and any other "details", in o ...021-October-30 }}</span> {{hilite | (relative to the top of the ''finished waterproofing system'') – the location of the drainage plane may affect the determinati
    45 KB (6,811 words) - 20:28, 9 July 2021
  • ...ecified ''system'' and may be required or simply is prudent for additional waterproofing protection in certain circumstances</span>. <li>accepted concrete-topped XPS insulation panels.
    58 KB (5,958 words) - 18:24, 12 November 2021
  • This section pertains to the waterproofing of roof penetrations, curbs, sleepers, drains and any other "details", in o ...021-October-30 }}</span> {{hilite | (relative to the top of the ''finished waterproofing system'') – the location of the drainage plane may affect the determinati
    56 KB (8,117 words) - 15:53, 27 August 2021
  • <big><big>'''Waterproofing Roofs'''</big></big> ====Insulation====
    6 KB (821 words) - 19:14, 31 January 2024
  • <big><big>'''Waterproofing Roofs'''</big></big> ====Insulation====
    8 KB (1,008 words) - 22:38, 30 January 2024
  • ...g Roof Systems<br>Grade-level Waterproofing Systems<br>Water-shedding Roof Systems ...S SHEET MEMBRANES Used in Roof Waterproofing and Grade-level Waterproofing Systems) (for membrane only)
    2 KB (348 words) - 19:38, 31 January 2024
  • ;Accepted for application in: Waterproofing Roof Systems ...ct Summary: '''Duro-Guard EPS Type II''' is a Type II Expanded Polystyrene insulation panels.
    2 KB (240 words) - 21:01, 31 January 2024
  • ...g Roof Systems<br>Grade-level Waterproofing Systems<br>Water-shedding Roof Systems ...y: '''Duro-Guard EPS Fiberglass Facer''' is a Type II expanded polystyrene insulation laminated to a fibreglass facer.
    2 KB (259 words) - 21:00, 31 January 2024
  • ;Accepted for application in: Waterproofing Roof Systems ...'''Duro-Guard® ISO III CG''' is a closed-cell Polyisocyanurate foam core insulation board with an integrally laminated, heavy, durable, and dimensionally stabl
    2 KB (264 words) - 21:04, 31 January 2024
  • ;Accepted for application in: Waterproofing Roof Systems ...®</sup> ISO HD''' is a 12.7 mm (1/2") thick high density Polyisocyanurate insulation panel specifically designed for use as a cover/recover board. It is manufac
    2 KB (265 words) - 21:10, 31 January 2024
  • ...g Roof Systems<br>Grade-level Waterproofing Systems<br>Water-shedding Roof Systems ...aminated during the manufacturing process to Duro-Guard ISO III rigid roof insulation. R-value is optimized with a thinner profile.
    2 KB (279 words) - 21:13, 31 January 2024
  • ;Accepted for application in: Waterproofing Roof Systems ...gned for use as a cover/recover board within mechanically fastened roofing systems only. It is manufactured on-line with an integrally laminated, fiber-reinfo
    2 KB (271 words) - 21:13, 31 January 2024
  • ...ard test method for the dynamic wind uplift resistance of membrane-roofing systems'' (latest edition). ...any material, structure or item of equipment that is placed on top of a ''waterproofing system''. Gravel or pavers constitute ''overburden'' when they do not funct
    55 KB (7,513 words) - 20:13, 22 April 2022
  • ...}} system''|| 2020-February-3 }}: {{hilite | means the top surface of a ''waterproofing system'' or ''water-shedding system'' that may include ballast or that supp ...slope, excludes water from a building and therefore waterproofs it. These systems are typically installed on slopes less than 1:4 (3” in 12”), on roofs o
    35 KB (4,946 words) - 17:05, 20 September 2021
  • ...ig><big><big><big>Notes to Standard for SBS-modified Bitumen Membrane Roof Systems</big></big></big></big></big> :<big>'''A-1.1.3.1.'''</big> ('''Permitted Roof Systems''')
    61 KB (8,812 words) - 18:01, 2 April 2024
  • ...}} system''|| 2020-February-3 }}: {{hilite | means the top surface of a ''waterproofing system'' or ''water-shedding system'' that may include ballast or that supp ...slope, excludes water from a building and therefore waterproofs it. These systems are typically installed on slopes less than 1:4 (3” in 12”), on roofs o
    35 KB (4,946 words) - 17:04, 20 September 2021
  • ...Insulation overlay boards are installed in most ''Conventionally Insulated Systems'' to</span> <li><span class="reference">protect ''heat-sensitive insulation'' materials from damage by heat and flame</span>.
    9 KB (1,275 words) - 21:22, 1 September 2021
  • ;'''Manufacturer''': [https://www.carlislesyntec.com/ '''Carlisle Syntec Systems Canada'''] ;Accepted for application in: Roof Waterproofing Systems
    2 KB (259 words) - 18:19, 28 June 2021
  • ...formation page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Divisio EPDM roof systems are single-ply membranes available in thicknesses ranging from a nominal 1.
    33 KB (4,674 words) - 16:01, 9 September 2021
  • :<big>[http://{{SERVERNAME}}/index.php?title=Insulation_Joints_and_Overlays Insulation Joints and Overlays<i class="fa fa-angle-double-right"></i>]</big> ...and_Modified_Protected_Roof_Systems Protected and Modified Protected Roof Systems <i class="fa fa-angle-double-right"></i>]</big>
    3 KB (468 words) - 21:32, 18 November 2022
  • <big>Water-shedding Roof Systems: Metals</big><br> <big><big><big><big><big>Standard for Architectural Sheet Metal (ASM) Roof Systems</big></big></big></big></big>
    260 KB (36,048 words) - 21:32, 5 April 2024
  • <big>Waterproofing Roof Systems: Flexible Membranes (Polymer-modified Bituminous)</big><br> <big><big><big><big><big><big>Standard for SBS-modified Bitumen Membrane Roof Systems</big></big></big></big></big></big>
    465 KB (62,115 words) - 14:08, 16 May 2024
  • <big>Waterproofing Roof Systems: Thermoset Membranes</big><br> <big><big><big><big><big><big>Standard for EPDM Membrane Roof Systems</big></big></big></big></big></big>
    423 KB (57,312 words) - 21:21, 5 April 2024
  • <big>Waterproofing Roof Systems: Thermosplastic Membranes</big><br> <big><big><big><big><big><big>Standard for TPO Membrane Roof Systems</big></big></big></big></big></big>
    420 KB (56,956 words) - 21:23, 5 April 2024
  • <big>Waterproofing Roof Systems: Thermosplastic Membranes</big><br> <big><big><big><big><big><big>Standard for PVC Membrane Roof Systems</big></big></big></big></big></big>
    415 KB (56,426 words) - 21:31, 5 April 2024
  • <big>Water-shedding Roof Systems: Bituminous</big><br> <big><big><big><big><big>Standard for Asphalt Shingle Roof Systems</big></big></big></big></big>
    235 KB (33,160 words) - 21:33, 5 April 2024
  • <big>Waterproofing Roof Systems: Liquid Membranes</big><br> ...<big><big><big><big>Standard for Hot Fluid-applied Rubberized Asphalt Roof Systems</big></big></big></big></big></big>
    294 KB (41,687 words) - 21:32, 5 April 2024
  • <big>Waterproofing Roof Systems: Flexible Membranes (Polymer-modified Bituminous)</big><br> <big><big><big><big><big><big>Standard for SBS-modified Bitumen Membrane Roof Systems</big></big></big></big></big></big>
    466 KB (62,224 words) - 14:08, 16 May 2024
  • ;Accepted for application in: Roof Waterproofing Systems<br>Water-shedding Systems (ASM) ;Product Summary: Closed cell expanded polystyrene (EPS) rigid roofing insulation manufactured in flat panels, sloped panels, and tapered applications. Cons
    2 KB (237 words) - 16:33, 24 June 2022
  • ;Accepted for application in: Roof Waterproofing Systems<br>Water-shedding Systems (ASM) ;Product Summary: Closed cell expanded polystyrene (EPS) rigid roofing insulation manufactured in flat panels, sloped panels, and tapered applications. Cons
    2 KB (237 words) - 16:34, 24 June 2022
  • ;Accepted for application in: Roof Waterproofing Systems<br>Water-shedding Systems (ASM) ;Product Summary: Closed cell expanded polystyrene (EPS) rigid roofing insulation manufactured in flat panels, sloped panels, and tapered applications. Cons
    2 KB (237 words) - 16:34, 24 June 2022
  • ;Accepted for application in: Roof Waterproofing Systems<br>Water-shedding Systems (ASM) ;Product Summary: Closed cell expanded polystyrene (EPS) rigid roofing insulation manufactured in flat panels, sloped panels, and tapered applications. Cons
    2 KB (237 words) - 16:35, 24 June 2022
  • ;Accepted for application in: Roof Waterproofing Systems<br>Water-shedding Systems (ASM) ;Product Summary: Closed cell expanded polystyrene (EPS) rigid roofing insulation manufactured in flat panels, sloped panels, and tapered applications. Cons
    2 KB (237 words) - 16:35, 24 June 2022
  • ;Accepted for application in: Roof Waterproofing Systems<br>Water-shedding Systems (ASM) ;Product Summary: Closed cell expanded polystyrene (EPS) rigid roofing insulation manufactured in flat panels, sloped panels, and tapered applications. Cons
    2 KB (237 words) - 16:34, 24 June 2022
  • <big>'''Classification (i.e., Architectural Metal Roofing, Insulation, Membranes, Asphalt Shingles)'''</big> ...oof Systems, Water-shedding Roof Systems, <br>or Grade-level Waterproofing Systems; be specific if it is limited to, say, ASM)
    2 KB (241 words) - 17:30, 10 February 2022
  • ...ig><big><big><big>Notes to Standard for SBS-modified Bitumen Membrane Roof Systems</big></big></big></big></big> :<big>'''A-1.1.3.1.'''</big> ('''Permitted Roof Systems''')
    61 KB (8,848 words) - 18:15, 2 April 2024
  • <big><big><big><big><big>Notes to Standard for EPDM Membrane Roof Systems</big></big></big></big></big> :<big>'''A-1.1.3.1.'''</big> ('''Permitted Roof Systems''')
    59 KB (8,541 words) - 18:06, 2 April 2024
  • <big><big><big><big><big>Notes to Standard for TPO Membrane Roof Systems</big></big></big></big></big> :<big>'''A-1.1.3.1.'''</big> ('''Permitted Roof Systems''')
    57 KB (8,230 words) - 18:16, 2 April 2024
  • <big><big><big><big><big>Notes to Standard for PVC Membrane Roof Systems</big></big></big></big></big> :<big>'''A-1.1.3.1.'''</big> ('''Permitted Roof Systems''')
    57 KB (8,230 words) - 18:16, 2 April 2024
  • ...}} system''|| 2020-February-3 }}: {{hilite | means the top surface of a ''waterproofing system'' or ''water-shedding system'' that may include ballast or that supp ...slope, excludes water from a building and therefore waterproofs it. These systems are typically installed on slopes less than 1:4 (3” in 12”), on roofs o
    35 KB (4,973 words) - 17:31, 22 November 2021
  • ...(adapted from ''ASTM D1079-18 Standard Terminology Relating to Roofing and Waterproofing'')|| 2021-June-30 }}. ...r function – ''<u>waterproofing</u> systems'' or ''<u>water-shedding</u> systems''. Within each classification, slope is defined as follows:
    25 KB (3,582 words) - 14:49, 23 December 2021
  • ...ard test method for the dynamic wind uplift resistance of membrane-roofing systems'' (latest edition). ...any material, structure or item of equipment that is placed on top of a ''waterproofing system''. Gravel or pavers constitute ''overburden'' when they do not funct
    55 KB (7,513 words) - 20:13, 22 April 2022
  • ...ority'' is responsible to specify {{hilite | the connections between the ''waterproofing'' or ''water-shedding system'' and ''walls'' or other building components, ...all finish must be installed at least 89 mm (3 ½”) above the ''finished waterproofing system''.
    36 KB (5,069 words) - 18:00, 18 May 2022
  • This section pertains to the waterproofing of roof penetrations, curbs, sleepers, drains and any other "details", in o ...021-October-30 }}</span> {{hilite | (relative to the top of the ''finished waterproofing system'') – the location of the ''drainage plane'' may affect the determi
    45 KB (6,830 words) - 19:36, 11 March 2022
  • ...mbrane Roof Systems'' or ''Modified Protected Membrane Systems''; in these systems, gravel ballast or pavers are used to secure the ''system'' materials again <li>a drainage layer beneath XPS insulation.
    14 KB (2,184 words) - 18:25, 15 November 2021
  • ...thetic finish to the ''roof system''. ''Linear metal flashings'' are not a waterproofing component. Consequently, the roofing membrane should be continuous beneath ...metal flashings. RoofStar-accepted pre-engineered products are accepted as systems and therefore the requirements in this Part for metal gauge, profile, secur
    28 KB (4,147 words) - 21:43, 27 April 2022
  • :;''Extensive Vegetated Roof Systems'': sometimes referred to as "eco-roofs", 'low-profile green roofs," "roofto ...t is situated on top of, and covering all or a portion of, a constructed ''waterproofing system''. ''Overburden'' includes, without limitation,
    32 KB (4,724 words) - 17:43, 16 November 2021
  • ...}} system''|| 2020-February-3 }}: {{hilite | means the top surface of a ''waterproofing system'' or ''water-shedding system'' that may include ballast or that supp ...slope, excludes water from a building and therefore waterproofs it. These systems are typically installed on slopes less than 1:4 (3” in 12”), on roofs o
    35 KB (4,973 words) - 17:31, 22 November 2021
  • ...(adapted from ''ASTM D1079-18 Standard Terminology Relating to Roofing and Waterproofing'')|| 2021-June-30 }}. ...r function – ''<u>waterproofing</u> systems'' or ''<u>water-shedding</u> systems''. Within each classification, slope is defined as follows:
    25 KB (3,582 words) - 14:50, 23 December 2021
  • ...ard test method for the dynamic wind uplift resistance of membrane-roofing systems'' (latest edition). ...any material, structure or item of equipment that is placed on top of a ''waterproofing system''. Gravel or pavers constitute ''overburden'' when they do not funct
    55 KB (7,513 words) - 20:12, 22 April 2022
  • ...ority'' is responsible to specify {{hilite | the connections between the ''waterproofing'' or ''water-shedding system'' and ''walls'' or other building components, ...all finish must be installed at least 89 mm (3 ½”) above the ''finished waterproofing system''.
    36 KB (5,070 words) - 14:53, 17 November 2021
  • This section pertains to the waterproofing of roof penetrations, curbs, sleepers, drains and any other "details", in o ...021-October-30 }}</span> {{hilite | (relative to the top of the ''finished waterproofing system'') – the location of the ''drainage plane'' may affect the determi
    45 KB (6,830 words) - 19:37, 11 March 2022
  • ...mbrane Roof Systems'' or ''Modified Protected Membrane Systems''; in these systems, gravel ballast or pavers are used to secure the ''system'' materials again <li>a drainage layer beneath XPS insulation.
    14 KB (2,184 words) - 18:37, 15 November 2021
  • ...thetic finish to the ''roof system''. ''Linear metal flashings'' are not a waterproofing component. Consequently, the roofing membrane should be continuous beneath ...metal flashings. RoofStar-accepted pre-engineered products are accepted as systems and therefore the requirements in this Part for metal gauge, profile, secur
    28 KB (4,147 words) - 21:43, 27 April 2022
  • :;''Extensive Vegetated Roof Systems'': sometimes referred to as "eco-roofs", 'low-profile green roofs," "roofto ...t is situated on top of, and covering all or a portion of, a constructed ''waterproofing system''. ''Overburden'' includes, without limitation,
    32 KB (4,724 words) - 17:43, 16 November 2021
  • ...><big><big>Notes to Standard for Hot Fluid-applied Rubberized Asphalt Roof Systems</big></big></big></big></big> :<big>'''A-1.1.3.1.'''</big> ('''Permitted Roof Systems''')
    41 KB (6,077 words) - 18:11, 2 April 2024
  • ...><big><big>Notes to Standard for Hot Fluid-applied Rubberized Asphalt Roof Systems</big></big></big></big></big> :<big>'''A-1.1.3.1.'''</big> ('''Permitted Roof Systems''')
    41 KB (6,080 words) - 18:16, 2 April 2024
  • <big>Water-shedding Roof Systems: Metals</big><br> <big><big><big><big><big>Standard for Architectural Sheet Metal (ASM) Roof Systems</big></big></big></big></big>
    261 KB (36,152 words) - 22:24, 5 April 2024
  • <big>Water-shedding Roof Systems: Bituminous</big><br> <big><big><big><big><big>Standard for Asphalt Shingle Roof Systems</big></big></big></big></big>
    236 KB (33,264 words) - 22:24, 5 April 2024
  • ;Accepted for application in: Roof Waterproofing Systems ...sulation assembly. Torch-applied membranes may be applied directly to the insulation, when permitted by RGC Standards.
    2 KB (257 words) - 18:59, 1 February 2023
  • <big><big>'''Waterproofing Roofs'''</big></big> ====Insulation====
    12 KB (1,434 words) - 21:49, 28 March 2024