Search results

Jump to: navigation, search

Search results

Page title matches

  • 174 bytes (24 words) - 16:38, 27 November 2015
  • #REDIRECT [[Section:A. About]]
    30 bytes (4 words) - 19:40, 24 November 2015
  • <big><big><big><big><big>Asphalt Shingles | Flashing a Masonry Chimney ([[Asphalt_Shingle_Systems_Standard#12.3.2.4. Curbs | Artic
    1 KB (171 words) - 14:35, 30 June 2022
  • ...a fa-hand-o-right" aria-hidden="true"></i> <big>Requesting and Specifying a RoofStar Guarantees</big>]]
    643 bytes (78 words) - 18:53, 27 July 2016
  • {{Special:PrefixIndex/Materials:A}}
    286 bytes (38 words) - 19:15, 12 October 2016
  • <big><big>Division A - Scope, Use of Standards, and Guarantee </big></big> <big><big><big><big><big>Part 4 - Specifying a RoofStar Guarantee</big></big></big></big></big>
    2 KB (304 words) - 16:39, 19 September 2023
  • ...standards as published in the '''RoofStar Roofing Practices Manual''' for a RoofStar 5-Year, RoofStar 10-Year or RoofStar 5-Year Waterproofing guarante
    1 KB (191 words) - 17:16, 22 August 2016
  • ...dards''''' as published in the '''RoofStar Roofing Practices Manual''' for a '''''RoofStar Guarantee''''', unless modified by the contract documents to
    1 KB (181 words) - 18:25, 19 August 2021
  • 51 bytes (6 words) - 17:05, 28 June 2022
  • :<big>[[Draft Divison A]]</big> ===Division A (Scope, Use of Standards, and Guarantee )===
    1 KB (195 words) - 15:12, 26 October 2023
  • <big><big><big><big><big>TPO | Membrane Termination A (Wall) ([[TPO_Roof_Systems_Standard#10.3.2.3._General_Application_Requireme ...lass=img-responsive | link=https://rpm.rcabc.org/images/f/fb/10.3.2.3.-TPO-A.png]]
    6 KB (842 words) - 16:35, 26 February 2024
  • <big><big><big><big><big>PVC | Membrane Termination A (Wall) ([[PVC_Roof_Systems_Standard#10.3.2.3._General_Application_Requireme ...lass=img-responsive | link=https://rpm.rcabc.org/images/f/fc/10.3.2.3.-PVC-A.png]]
    6 KB (842 words) - 16:41, 26 February 2024
  • <big><big><big><big><big>SBS | Membrane Termination A (Wall) ([[SBS_Roof_Systems_Standard#10.3.2.3._General_Application_Requireme ...lass=img-responsive | link=https://rpm.rcabc.org/images/d/dd/10.3.2.3.-SBS-A.png]]
    6 KB (861 words) - 15:55, 26 February 2024
  • <big><big><big><big><big>EPDM | Membrane Termination A (Wall) ([[EPDM_Roof_Systems_Standard#10.3.2.3._General_Application_Requirem ...ass=img-responsive | link=https://rpm.rcabc.org/images/5/53/10.3.2.3.-EPDM-A.png]]
    6 KB (840 words) - 16:26, 26 February 2024
  • [[File:Division A page thumb.jpg|class=img-responsive | link=http://rpm.rcabc.org/images/8/81
    975 bytes (130 words) - 17:44, 2 September 2021
  • 0 bytes (0 words) - 18:19, 2 September 2021
  • :<big><big><big><big><big>Division A: Scope, Use of Standards, and Guarantee</big></big></big></big></big> [[File:Division A page thumb.jpg|class=img-responsive | link=http://rpm.rcabc.org/images/8/81
    1 KB (185 words) - 16:52, 31 January 2022

Page text matches

  • <big>[[Division A | '''Division A: Scope, Use of Standards, and Guarantee''']]</big> ...chnical-updates/" target="_blank"><big><big>Technical Updates</big></big></a></html>
    11 KB (1,512 words) - 16:30, 7 May 2024
  • ...Planning session at which the members in attendance strongly advocated for a new name and increased marketing efforts aimed to build the Guarantee Progr Enter a word, a phrase or a section number into the search window and all of the sections these words a
    3 KB (537 words) - 20:47, 21 October 2016
  • ...S for a RoofStar Five (5) Year or Ten (10) Year Roofing Guarantee, and for a RoofStar Five (5) Year Waterproofing Guarantee.</big> This list of acceptable materials is not intended for use as a comparison of material performance or quality. It is the sole responsibilit
    4 KB (526 words) - 16:18, 17 March 2019
  • ...ete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority. ;'''Product Summary''': A breathable non-woven waterproof roofing underlayment.
    1,008 bytes (127 words) - 16:23, 26 February 2018
  • The ability of a membrane to resist being worn away by contact with a moving abrasive surface, such as foot traffic, mechanical equipment, wind-b
    165 bytes (26 words) - 20:12, 5 November 2018
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...re not readily flammable and do not carry or communicate fire; they afford a fairly high degree of fire protection to the roof deck; they do not slip fr
    5 KB (808 words) - 16:06, 9 September 2021
  • The following is a partial listing of publications by WorkSafeBC: :A complete record of regulations which WorkSafeBC has the power to enforce in
    3 KB (432 words) - 14:39, 9 June 2017
  • -- Get the argument tables. If we were passed a valid frame object, get the -- passed a valid frame object, we are being called from another Lua module
    9 KB (1,372 words) - 22:27, 2 July 2015
  • ...up roofing felts. While offering the higher performance and versatility of a flexible membrane, SBS-modified roofing membranes are also generally compat ...ane (these fibers may be glass, polyester, or a blend of the two), and (3) a surface coating, such as stone or ceramic granules. The performance of thes
    5 KB (703 words) - 16:54, 23 November 2015
  • ...SYTEMS for a RoofStar 5-year Guarantee, RoofStar 10-year Guarantee, or for a RoofStar 15-year Guarantee.</big> ...Manual''. Furthermore, these tables and lists are not intended for use as a comparison of material performance or quality. It is the sole responsibilit
    13 KB (1,880 words) - 19:18, 1 February 2024
  • ...SYTEMS for a RoofStar 5-year Guarantee, RoofStar 10-year Guarantee, or for a RoofStar 15-year Guarantee.</big> ...Manual''. Furthermore, these tables and lists are not intended for use as a comparison of material performance or quality. It is the sole responsibilit
    3 KB (413 words) - 21:46, 14 June 2023
  • <big>What goes into a RoofStar Guaranteed roof? Learn about the Essential Elements here, and exp ...Roof|<i class="fa fa-hand-o-right" aria-hidden="true"></i> <big>Building a Roof</big>]]
    2 KB (290 words) - 20:13, 22 August 2016
  • #REDIRECT [[Section:A. About]]
    30 bytes (4 words) - 19:40, 24 November 2015
  • ...p roofing felts. While offering the higher performance and versatility of a flexible membrane, these products also offer the practical advantages of bi ...suitable bitumen. A well dispersed, homogeneous polymer mixture will form a continuous rubber network throughout the bitumen.
    22 KB (3,281 words) - 21:46, 17 July 2017
  • ...ete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority. ...ry for high insulation values and in a stair stepped fashion, facilitating a positive slope to drain.
    3 KB (474 words) - 21:16, 12 February 2019
  • ...acturers&#8217; specifications and RoofStar Guarantee Standards to develop a system acceptable to both the manufacturer and the '''''RoofStar Guarantee '''NOTE''': 'PDF' shown after a file name below indicates a downloadable print sheet is available for Construction Details. Click on t
    2 KB (277 words) - 21:16, 30 August 2021
  • <big>[[Division A | '''Division A: Scope, Use of Standards, and Guarantee''']]</big> <sup><span style="color: ...dards necessary to qualify roof and grade-level waterproofing projects for a '''''RoofStar Guarantee'''''.
    11 KB (1,581 words) - 19:51, 15 November 2021
  • ...bership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org] ;Country of Manufacture: U.S.A.
    2 KB (288 words) - 22:14, 8 September 2021
  • ...s ''Primary'' or ''Secondary Materials'' together, or is connected to/with a ''Primary'' or ''Secondary material'', but does not by its nature (apart fr ...cessory'' recommended or endorsed by the ''Guarantor''. The preparation of a detailed specification is the responsibility of the ''Design Authority''.
    2 KB (233 words) - 15:23, 27 October 2020
  • ...talled 4” or more above the maximum water line, and gutters must include a scupper overflow drain. || 2017-April-22 }}). Also refer to [[RoofStar Gua ...erlay or eave protection membrane must overlap built-in gutter membrane by a minimum of 200 mm (8") and be installed in shingle fashion (not shown for c
    3 KB (356 words) - 14:32, 30 June 2022
  • ...ield application are presently available as a catalyzed resin that require a woven reinforcement inter-ply for strength. To ensure quality installation
    1 KB (178 words) - 21:51, 7 September 2021
  • ...the marketplace may be specified and installed in a ''project'' for which a '''''RoofStar Guarantee''''' is required – only those that satisfy the ac ...come a member of the RCABC, visit our [http://www.rcabc.org/members/become-a-member/ '''website'''].
    22 KB (3,050 words) - 16:20, 12 December 2023
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...inous roofing systems. However, some systems require that applicators use a propane-fuelled open flame torch to adhere the membrane. When working with
    14 KB (2,333 words) - 16:39, 9 February 2022
  • ...; specifications and the '''''RoofStar Guarantee Standards''''' to develop a system acceptable to both the manufacturer and the '''''RoofStar Guarantee <li>[[SBS Membrane Termination A | Membrane Termination A]]
    7 KB (906 words) - 16:03, 26 February 2024
  • ;(A) [[Asphalt Shingle Systems Standard#AShDECKS|'''Acceptable Deck''']]
    3 KB (343 words) - 14:29, 30 June 2022
  • ...) minimum on sides and 150 mm (6") minimum on ends. (See Section 3.1.5 for a list of accepted eave protection and underlayment.) (A) <b>Acceptable Deck</b>
    2 KB (260 words) - 22:52, 21 December 2015
  • ...equirements for side and end laps; use acceptable fasteners, or adhere (if a self-adhering membrane) in keeping with the manufacturer’s published requ ;(A) [[Asphalt Shingle Systems Standard#AShDECK|'''Acceptable Deck''']]
    3 KB (344 words) - 14:13, 5 October 2022
  • ...equirements for side and end laps; use acceptable fasteners, or adhere (if a self-adhering membrane) in keeping with the manufacturer’s published requ ;(A) [[Asphalt Shingle Systems Standard#AShDECK|'''Acceptable Deck''']]
    3 KB (351 words) - 14:11, 5 October 2022
  • <big><big><big><big><big>Asphalt Shingles | Flashing a Masonry Chimney ([[Asphalt_Shingle_Systems_Standard#12.3.2.4. Curbs | Artic
    1 KB (171 words) - 14:35, 30 June 2022
  • ...b>: Formed from a minimum 26 guage galvanized steel diverters shall extend a minimum 125 mm (5") up vertical surfaces 100 mm (4") to the roof. ...be angle trimmed and a drip edge formed at the outlet. Outlet is to extend a minimum of 25mm (1") lower than the edge of the roof material and lead wate
    1 KB (196 words) - 22:57, 21 December 2015
  • : Extended a minimum 100mm (4") beyond corners, interwoven with shingles and step flashi ;(6) '''Capillary Section''': A capillary tab is to be extended off the end of the back pan to lead water a
    2 KB (312 words) - 14:39, 30 June 2022
  • ::Click below for a printable version of this page (N/A) ...'''Hook securement strip''']]: In this particular rake edge configuration, a similar strip is installed along the rake to secure the flush rake-edge fla
    3 KB (473 words) - 18:24, 28 June 2022
  • A '''''RoofStar Guarantee''''' is available for almost any roof design, provi ...All new materials incorporated into a ''Project'' intended to qualify for a '''''RoofStar Guarantee''''' must be expressly accepted by the RGC and list
    9 KB (1,253 words) - 17:05, 10 December 2021
  • ...'''' or '''''RoofStar 15-year Guarantee'''''. Requirements to qualify for a '''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under ...ganization_of_RPM_and_Standards#2.3.1.2._Authority_and_Conflict | Division A, Article 2.3.1.2.]] shall be applied.
    416 KB (56,532 words) - 22:23, 5 April 2024
  • ...'''' or '''''RoofStar 15-year Guarantee'''''. Requirements to qualify for a '''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under ...ganization_of_RPM_and_Standards#2.3.1.2._Authority_and_Conflict | Division A, Article 2.3.1.2.]] shall be applied.
    424 KB (57,418 words) - 22:20, 5 April 2024
  • ...'''' or '''''RoofStar 15-year Guarantee'''''. Requirements to qualify for a '''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under ...ganization_of_RPM_and_Standards#2.3.1.2._Authority_and_Conflict | Division A, Article 2.3.1.2.]] shall be applied.
    421 KB (57,062 words) - 22:20, 5 April 2024
  • ...'''' or '''''RoofStar 15-year Guarantee'''''. Requirements to qualify for a '''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under ...ganization_of_RPM_and_Standards#2.3.1.2._Authority_and_Conflict | Division A, Article 2.3.1.2.]] shall be applied.
    296 KB (41,811 words) - 22:23, 5 April 2024
  • ...a fa-hand-o-right" aria-hidden="true"></i> <big>Requesting and Specifying a RoofStar Guarantees</big>]]
    643 bytes (78 words) - 18:53, 27 July 2016
  • ...SYTEMS for a RoofStar 5-year Guarantee, RoofStar 10-year Guarantee, or for a RoofStar 15-year Guarantee.</big> ...Manual''. Furthermore, these tables and lists are not intended for use as a comparison of material performance or quality. It is the sole responsibilit
    13 KB (1,636 words) - 17:02, 5 January 2024
  • ...t are not recommended or endorsed by the ''Guarantor''. The preparation of a detailed specification is the responsibility of the ''Design Authority''. ...bership list and contact information at [http://www.rcabc.org/members/find-a-member/ '''www.rcabc.org''']
    1 KB (213 words) - 14:42, 26 October 2023
  • ...bership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org] ...d data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For
    5 KB (684 words) - 14:23, 27 October 2023
  • * {{hilite | A First Observation that includes an evaluation of the supporting deck surfac * {{hilite | Regular observations, on a daily basis when possible or as otherwise mandated by the RoofStar Fee Calc
    2 KB (284 words) - 18:25, 19 August 2021
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...m, as they relate to the specific project. Many factors affect the life of a roof system and should be of concern to the owner and design authority.
    3 KB (386 words) - 15:33, 9 September 2021
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan
    2 KB (308 words) - 15:59, 9 September 2021
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...system, HVAC units and, possibly, landscaping. Most decks must also act as a diaphragm, transmitting wind or seismic lateral forces to the buildings str
    20 KB (2,969 words) - 16:06, 9 September 2021
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...placed over steel decks to provide a level surface for the membrane, or as a thermal barrier between the roof deck and combustible insulation.
    1 KB (198 words) - 15:33, 9 September 2021
  • ...ly varied by the ''Guarantor'' under the terms of the Guarantee issued for a ''project''. <li>The requirements for a '''''RoofStar 15-year Guarantee''''' shall be as described in Part 1 of the
    11 KB (1,608 words) - 22:03, 3 May 2021
  • <big><big>Division A - Scope, Use of Standards, and Guarantee </big></big> .... In 2016, the wiki-based ''RPM'' was restructured to form five Divisions, A through E.
    15 KB (2,132 words) - 19:02, 18 August 2023
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...(or shelter) that is not governed by the exterior environment. The roof is a fundamental component of this design and must perform several functions. As
    23 KB (3,279 words) - 15:42, 9 September 2021
  • '''NOTE''': Presently, there are no butyl membranes accepted for use in a '''''RoofStar Guaranteed''''' Waterproofing assembly.
    406 bytes (46 words) - 14:10, 27 July 2021
  • ...lished Technical Data sheets, but this information not intended for use as a comparison of material performance or quality. It is the sole responsiblity ...s, to provide a minimum double coverage. Capping must be installed in such a manner that nails are not exposed. Continuous proprietary ridge venting s
    3 KB (399 words) - 14:12, 27 July 2021
  • ...ture monitoring sensor grids are pavers on pedestals and gravel ballast to a maximum 100mm (4") thick . Moisture monitoring sensor grids<b> shall </b>be :Flood Testing is <b>not a recommended practice</b> but is at the discretion of the design authority o
    2 KB (249 words) - 22:45, 9 November 2016
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they
    2 KB (225 words) - 21:24, 7 September 2021
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan * the insulation may be incompatible with the membrane, resulting in a loss of physical properties
    4 KB (532 words) - 15:44, 9 September 2021
  • [[File:10.3.7.1.jpg| link=http://rpm.rcabc.org/images/a/a0/10.3.7.1.jpg | class=img-responsive]] ...ndard#PART_12|'''Protected Membrane Roof Assembly''']]: Flashing to extend a minimum 200 mm (8") above finished roof surface (pavers, ballast, or walkwa
    3 KB (360 words) - 18:16, 27 October 2023
  • ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Deck''']]:
    2 KB (262 words) - 18:33, 27 June 2022
  • ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure
    2 KB (284 words) - 18:34, 27 June 2022
  • ;(A) [[TPO Roof Systems Standard#PART_2|'''Acceptable Deck''']]
    3 KB (429 words) - 21:34, 27 June 2022
  • ...]]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ;(A) [[EPDM Roof Systems Standard#PART_2|'''Acceptable Deck''']]
    3 KB (367 words) - 21:52, 27 June 2022
  • ...]]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ;(A) [[RoofStar Guarantee Standards for EPDM Roof Assemblies#EPDMDECKS|'''Accep
    3 KB (351 words) - 16:48, 23 October 2017
  • ...]]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ;(A) [[RoofStar Guarantee Standards for EPDM Roof Assemblies#EPDMDECKS|'''Accep
    3 KB (347 words) - 16:48, 23 October 2017
  • ...]]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ;(A) [[RoofStar Guarantee Standards for EPDM Roof Assemblies#EPDMDECKS|'''Accep
    3 KB (332 words) - 16:49, 23 October 2017
  • ...]]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ;(A) [[RoofStar Guarantee Standards for EPDM Roof Assemblies#EPDMDECKS|'''Accep
    3 KB (334 words) - 18:30, 23 October 2017
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...re secured to the roof deck by means of mechanical fastening, adhesive, or a combination of both.
    7 KB (999 words) - 15:42, 9 September 2021
  • This is the first part of a multi-part series on the Building Code and roofing: ...t is all done, the commissioned building must be safe, accessible, provide a healthy environment for people, energy efficient, and it must capably prote
    21 KB (3,118 words) - 16:32, 16 March 2023
  • ...u> </u>than the box height with a 12.7mm (&#189;") drip edge. Installed in a thin bed of compatible mastic. Interface between outside wall and scupper s ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure
    3 KB (440 words) - 18:14, 27 October 2023
  • ...u> </u>than the box height with a 12.7mm (&#189;") drip edge. Installed in a bed of compatible mastic. Interface between outside wall and scupper shoul ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure
    3 KB (420 words) - 18:15, 27 October 2023
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...ey are produced naturally or by industrial distillation and are usually in a solid or semi-solid state at ambient temperatures.
    15 KB (2,293 words) - 15:33, 9 September 2021
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan A combination of technological and economic factors has brought about the inc
    23 KB (3,307 words) - 15:57, 9 September 2021
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...tuminous, and built-up roof membranes. In addition, the top ply or felt in a BUR must be protected from weather exposure to prevent &#8220;wicking&#8221
    8 KB (1,280 words) - 16:25, 9 September 2021
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...ubject to many life-shortening elements, and it must function as more than a waterproofing agent. In addition to ultraviolet degradation, thermal cyclin
    11 KB (1,624 words) - 16:21, 9 September 2021
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan Water-shedding materials are used on roofs that typically have a slope of 1:3 (4" in 12") or greater. Generally, the materials installed on
    2 KB (256 words) - 16:19, 9 September 2021
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...ange on the remaining three sides. Continuous ridge air vents must provide a minimum of 50 mm (2”) of flashing flange to overlap roofing material on e
    6 KB (911 words) - 15:33, 9 September 2021
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...water to freeze and form an ice dam. As the ice dam grows bigger, it forms a barrier, which prevents water from draining. The water backs up behind the
    3 KB (400 words) - 15:35, 9 September 2021
  • {{Special:PrefixIndex/Materials:A}}
    286 bytes (38 words) - 19:15, 12 October 2016
  • ...' specifications and the '''''RoofStar Guarantee Standards''''' to develop a system acceptable to both the manufacturer and the '''''RoofStar Guarantee <li>[[TPO Membrane Termination A | Membrane Termination A]]
    3 KB (435 words) - 16:39, 26 February 2024
  • ...' specifications and the '''''RoofStar Guarantee Standards''''' to develop a system acceptable to both the manufacturer and the '''''RoofStar Guarantee <li>[[EPDM Membrane Termination A | Membrane Termination A]]
    3 KB (412 words) - 16:30, 26 February 2024
  • ...adhesive. Must be carried to the outside of the parapet or vertically to a minimum of 200 mm (8”) above the finished roof surface. Welded or adhere ;(A) [[RoofStar Guarantee Standards for TPO/PVC Roof Assemblies#TPODECKS|'''Acc
    4 KB (462 words) - 17:01, 23 October 2017
  • ;(A) [[EPDM Roof Systems Standard#PART_2|'''Acceptable Deck''']]
    2 KB (281 words) - 21:53, 27 June 2022
  • ;(A) [[EPDM Roof Systems Standard#PART_2|'''Acceptable Deck''']]
    3 KB (422 words) - 21:33, 27 June 2022
  • ...]]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ;(A) [[RoofStar Guarantee Standards for TPO/PVC Roof Assemblies#TPODECKS|'''Acc
    3 KB (382 words) - 17:02, 23 October 2017
  • ...]]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ;(A) [[RoofStar Guarantee Standards for TPO/PVC Roof Assemblies#TPODECKS|'''Acc
    3 KB (360 words) - 17:01, 23 October 2017
  • ...]]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ;(A) [[RoofStar Guarantee Standards for TPO/PVC Roof Assemblies#TPODECKS|'''Acc
    3 KB (374 words) - 17:02, 23 October 2017
  • ...]]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ;(A) [[RoofStar Guarantee Standards for TPO/PVC Roof Assemblies#TPODECKS|'''Acc
    3 KB (373 words) - 17:02, 23 October 2017
  • ...' specifications and the '''''RoofStar Guarantee Standards''''' to develop a system acceptable to both the manufacturer and the '''''RoofStar Guarantee <li>[[Asphalt Shingles - Flashing a Masonry Chimney| Flashing a Masonry Chimney]]
    5 KB (654 words) - 15:53, 30 June 2022
  • ...ore, the ''Design Authority'' may wish to consult with the manufacturer of a chosen material before specifying it. For more information about the use of insulation overlays in a Water-shedding Roof System, consult the specific roof system standards publ
    1 KB (185 words) - 14:15, 27 July 2021
  • Materials to be covered by the Guarantee Program must be acceptable to RGC. A listing is published in the RCABC Roofing Practices Manual, Section ('''''R Materials to be covered by the Guarantee Program must be acceptable to RGC. A listing is published in the RCABC Roofing Practices Manual, Section C. See
    1 KB (188 words) - 23:21, 21 December 2015
  • ..._Standard Standard for Cedar Shake and Shingle Roof Systems]''' to develop a system acceptable to both the manufacturer and the '''''RoofStar Guarantee :[[File:Cedar Shingles.jpg| link=http://rpm.rcabc.org/images/a/a6/Cedar_Shingles.jpg | 300 px]]
    2 KB (277 words) - 23:44, 27 February 2023
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they
    2 KB (266 words) - 21:05, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they
    2 KB (264 words) - 21:05, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ...n 450 mm (18") shall be laid between courses of cedar shakes starting from a distance equal to double the weather exposure from the butt. On open sheath
    3 KB (493 words) - 21:06, 7 September 2021
  • ...; specifications and the '''''RoofStar Guarantee Standards''''' to develop a system acceptable to both the manufacturer and the '''''RoofStar Guarantee '''NOTE''': 'PDF' shown after a file name below indicates a downloadable print sheet is available for Construction Details. Click on t
    3 KB (412 words) - 20:49, 3 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ;(A) [[Grade-level Waterproofing Standard#WPDECK | '''Acceptable Deck''']]: Con
    4 KB (458 words) - 21:14, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ...with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelli
    4 KB (454 words) - 21:14, 7 September 2021
  • ::Click below for a printable version of this page (N/A) ...4 mm (6”) or more above the maximum water line, and gutters must include a scupper overflow drain. || 2017-April-22 }}).
    3 KB (368 words) - 16:01, 18 March 2024
  • ..."background-color: #ffffcc;" | The information on this page is intended as a general guide for specifiers. '''''RoofStar Guarantees''''' are currently < ...e_Systems_Standard Standard for Tile and Slate Roof Systems]''' to develop a system acceptable to both the manufacturer and the '''''RoofStar Guarantee
    2 KB (357 words) - 20:49, 3 September 2021
  • ::Click below for a printable version of this page (N/A) ...'''Hook securement strip''']]: In this particular rake edge configuration, a similar strip is installed along the rake to secure the flush rake-edge fla
    3 KB (472 words) - 18:24, 28 June 2022
  • <big>[[Division A | '''Division A: Scope, Use of Standards, and Guarantee''']]</big> ...chnical-updates/" target="_blank"><big><big>Technical Updates</big></big></a></html>
    11 KB (1,555 words) - 21:08, 1 August 2023
  • Materials to be covered by the Guarantee Program must be acceptable to RGC. A listing is published in the RCABC Roofing Practices Manual, Section ('''''R Materials to be covered by the Guarantee Program must be acceptable to RGC. A listing is published in the RCABC Roofing Practices Manual, Section C. See
    1 KB (188 words) - 23:09, 21 December 2015
  • ;(A) [[Asphalt Shingle Systems Standard#AShDECKS|'''Acceptable Deck''']]
    3 KB (386 words) - 14:29, 30 June 2022
  • Materials to be covered by the Guarantee Program must be acceptable to RGC. A listing is published in the RCABC Roofing Practices Manual, Section ('''''R Materials to be covered by the Guarantee Program must be acceptable to RGC. A listing is published in the RCABC Roofing Practices Manual, Section C. See
    1 KB (188 words) - 23:11, 21 December 2015
  • ;(A) [[SBS Roof Systems Standard#PART_2|'''Supporting Deck Structure''']]
    4 KB (607 words) - 18:19, 27 October 2023
  • ...oof field plane. The exit point for the penetration must be shielded with a hood and sloped downward to shed water. Secure separate lid with screw-typ ...elf-adhering or torch-applied base membrane material, it is fashioned with a hole to fit around the penetration flashing and is sealed to the flashing a
    4 KB (630 words) - 18:16, 27 October 2023
  • [[File:D1.7.8-3.jpg| link=http://rpm.rcabc.org/images/a/a0/D1.7.8-3.jpg | class=img-responsive]] ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure
    3 KB (420 words) - 18:14, 27 October 2023
  • ...s Standard#PART_10|'''Base Membrane (flashing)''']]: Carried vertically up a wall or parapet at least 200 mm (8”), and onto the roof field at least 10 ...vertically past the termination of the base membrane flashing, to provide a positive seal at the top edge.
    3 KB (474 words) - 18:18, 27 October 2023
  • ;(A) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMDECK|'''Acceptab
    2 KB (291 words) - 16:27, 26 April 2019
  • ::Click below for a printable version of this page (N/A) ;(A) [[ASM Roof Systems Standard#PART_2 |'''Acceptable deck''']]
    2 KB (328 words) - 14:53, 28 June 2022
  • ::Click below for a printable version of this page (N/A) ;(A) [[ASM Roof Systems Standard#PART_2|'''Acceptable deck''']]
    2 KB (298 words) - 14:55, 28 June 2022
  • ::Click below for a printable version of this page (N/A) ...ems. For slopes less than 1:3, the entire roof slope must be covered with a <u>self-adhered</u> underlayment.
    4 KB (483 words) - 18:24, 28 June 2022
  • ;(A) [[ASM Roof Systems Standard#PART_2|'''Acceptable Deck''']]
    2 KB (297 words) - 18:04, 28 June 2022
  • ::Click below for a printable version of this page (N/A) ...rs 200 mm (8") o/c. Metal roof panel to metal valley panel overlap must be a minimum of 125 mm (5"). See '''10.3.5.2.2''' ('''5''').
    3 KB (407 words) - 18:24, 28 June 2022
  • ::Click below for a printable version of this page (N/A) ...d#8.1.3.5. Ventilation Beneath Panels|'''Ventilation beneath panels''']]: A ventilation space is required on slopes less than 1:3; entangled mesh (show
    3 KB (416 words) - 18:24, 28 June 2022
  • ::Click below for a printable version of this page (N/A) ...te for roof system materials. Here, a deck overlay is provided to support a continuous AVB layer.
    4 KB (540 words) - 17:25, 28 June 2022
  • ::Click below for a printable version of this page (N/A) ...rd#8.1.3.5. Ventilation Beneath Panels|'''Ventilation beneath panels''']]: A ventilation space is required on slopes less than 1:3; entangled mesh (show
    3 KB (432 words) - 19:00, 28 June 2022
  • [[File:8.1.4.9.1.jpg| link=http://rpm.rcabc.org/images/a/ab/ASM_11.1.2_Pipe_Flashing%2C_Split_Panel.jpg | class=img-responsive]] ...derside of the metal panels (See [[Notes to ASM Standard#A-8.1.3.5. | Note A-8.1.3.5.]]).
    4 KB (537 words) - 17:35, 17 March 2023
  • ::Click below for a printable version of this page (N/A) ...rd#8.1.3.5. Ventilation Beneath Panels|'''Ventilation beneath panels''']]: A ventilation space is required on slopes less than 1:3; entangled mesh (show
    4 KB (530 words) - 20:11, 28 June 2022
  • ::Click below for a printable version of this page (N/A) ...ms Standard#8.1.3.5. Ventilation Beneath Panels|'''Ventilation layer''']]: A ventilation space is required on slopes less than 1:3; entangled mesh (show
    3 KB (370 words) - 17:54, 28 June 2022
  • ::Click below for a printable version of this page (N/A) ...oof Systems Standard#ASMCLIP |'''Architectural metal panel clip''']]: When a ventilation material is specified or required (Item 2), clips must be suppo
    3 KB (430 words) - 16:23, 28 June 2022
  • ;(A) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMDECK|'''Acceptab
    2 KB (310 words) - 16:34, 26 April 2019
  • ::Click below for a printable version of this page (N/A) ...ems. For slopes less than 1:3, the entire roof slope must be covered with a <u>self-adhered</u> underlayment.
    3 KB (464 words) - 17:31, 28 June 2022
  • ::Click below for a printable version of this page (N/A) ...ic (2-ply SBS) or Sealant (Single plies): Drain flange must be embedded in a membrane-compatible mastic and secured to the gutter structure.
    5 KB (611 words) - 18:17, 12 March 2024
  • ...Underlay:</b> RGC accepted self-adhered modified bituminous membrane with a slip sheet overlay of lightweight resin sized or non-asphaltic building pap ...um thickness cold-rolled copper conforming to ASTM B370-98, roll-formed to a maximum panel width of 432 mm (17") with maximum 25 mm (1") tall standing s
    3 KB (379 words) - 22:50, 21 December 2015
  • ...ws with a minimum penetration of 12.5 mm (1/2"). Fasten to wood deck using a minimum of two # 8-14, 4 mm by 31 mm (1 1/4") screws. ...thickness zinc conforming to European standard EN 988-1996, roll-formed to a maximum panel width of 425 mm (17") with maximum 25 mm (1") tall standing s
    3 KB (421 words) - 22:51, 21 December 2015
  • ...' specifications and the '''''RoofStar Guarantee Standards''''' to develop a system acceptable to both the manufacturer and the '''''RoofStar Guarantee
    5 KB (642 words) - 20:11, 28 June 2022
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they [[File:7.4.1.2.3.jpg| link=http://rpm.rcabc.org/images/a/a9/7.4.1.2.3.jpg | class=img-responsive]]
    4 KB (607 words) - 21:09, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ...erlay or eave protection membrane must overlap built-in gutter membrane by a minimum of 200 mm (8") and be installed in shingle fashion (not shown for c
    3 KB (425 words) - 21:06, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ...erlay or eave protection membrane must overlap built-in gutter membrane by a minimum of 200 mm (8") and be installed in shingle fashion (not shown for c
    3 KB (401 words) - 21:12, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ;(2) Sealant: A sealant, mortar or plaster cement should be applied to the tops of the fiel
    2 KB (370 words) - 21:07, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they
    2 KB (311 words) - 21:07, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ...or problematic roof.Flashing for a wall termination should lap the tile by a minimum of 100 mm (4"). Material should be the 26-Ga. pre-painted galvanize
    3 KB (375 words) - 21:08, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ;(4) Mortar or mastic: A mortar or mastic bedding should be applied to the tops of the concrete tile
    2 KB (359 words) - 21:08, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ...r the course of tile penetrated by the pipe and under the next course with a 75 mm (3") min. lap.
    2 KB (298 words) - 21:08, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they (A) <b>Acceptable Deck</b>
    3 KB (387 words) - 21:09, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they Valleys on a slate roof can be done in several ways including swept, laced, mitred and o
    3 KB (377 words) - 21:10, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they Hips on a slate roof can be either mitred, saddled or have a metal flashing.
    2 KB (366 words) - 21:10, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they Ridges have several traditional styles including saddled or a metal flashing. Ridges are installed after the field slates are installed f
    3 KB (379 words) - 21:11, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they :Step flashings are used where a long vertical detail (chimneys, walls, skylights) runs parallel to the slop
    3 KB (439 words) - 21:11, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they
    2 KB (277 words) - 21:11, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ;(A) [[Grade-level Waterproofing Standard#WPDECK | '''Acceptable Deck''']]: Con
    4 KB (484 words) - 21:15, 7 September 2021
  • ...]]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ;(A) [[TPO Roof Systems Standard#PART_2|'''Acceptable Deck''']]
    3 KB (383 words) - 21:38, 27 June 2022
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ...g (stripping)''']]: Carried up wall minimum 200 mm (8") above deck surface a minimum of 100mm (4") above top surface of waterproofing assembly. Typical
    4 KB (527 words) - 21:15, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they [[File:F1.7.5.jpg| link=http://rpm.rcabc.org/images/a/af/F1.7.5.jpg | class=img-responsive]]
    4 KB (527 words) - 21:16, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ;(A) [[Grade-level Waterproofing Standard#WPDECK | '''Acceptable Deck''']]: Con
    5 KB (580 words) - 21:16, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ...above the primary waterproofing membrane. Low door sills shall incorporate a metal water stop flashing that is mechanically attached to the backside of
    4 KB (560 words) - 21:17, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ...: Carried up walls a minimum 200 mm (8") above membrane surface (Deck) and a minimum of 100mm (4") above top surface of permeable waterproofing wearing
    4 KB (596 words) - 21:17, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they [[File:9.6.9.jpg| link=http://rpm.rcabc.org/images/a/a6/9.6.9.jpg | class=img-responsive]]
    4 KB (463 words) - 21:18, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ...nimum 38 mm (1 &frac12;") wide x 12 mm (1/2") thick C-channel, formed from a minimum 22 gauge galvanized or pre-finished steel.
    4 KB (475 words) - 21:21, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ;(A) Acceptable Deck: Concrete slab shown
    4 KB (467 words) - 21:21, 7 September 2021
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ;(A) [[Grade-level Waterproofing Standard#WPDECKn| '''Acceptable Deck''']]: Con
    3 KB (413 words) - 21:22, 7 September 2021
  • ...s Standard#PART_10|'''Base Membrane (flashing)''']]: Carried vertically up a wall or parapet at least 200 mm (8”), and onto the roof field at least 10 ...vertically past the termination of the base membrane flashing, to provide a positive seal at the top edge.
    3 KB (472 words) - 17:57, 27 October 2023
  • ...s Standard#PART_10|'''Base Membrane (flashing)''']]: Carried vertically up a wall or parapet at least 200 mm (8”), and onto the roof field at least 10 ...vertically past the termination of the base membrane flashing, to provide a positive seal at the top edge.
    3 KB (446 words) - 17:36, 27 October 2023
  • ...m height requirement for parapets (127 mm (5”)), illustrated in Drawing (A). :Installed as required in Part 10 and applied as the second or third of a multi-ply membrane system, providing required coverage above the ''finished
    4 KB (633 words) - 21:01, 1 November 2022
  • <big><big>Division A - Scope, Use of Standards, and Guarantee </big></big> <big><big><big><big><big>Part 4 - Specifying a RoofStar Guarantee</big></big></big></big></big>
    2 KB (304 words) - 16:39, 19 September 2023
  • ...s Standard#PART_10|'''Base Membrane (flashing)''']]: Carried vertically up a wall or parapet (membrane flashing must extend up the vertical plane, and a ...top edge. Membrane flashing must be protected from UV light exposure; use a granulated surface membrane (as illustrated) or cover with metal flashing.
    5 KB (661 words) - 17:37, 27 October 2023
  • ...hing''']]: As required by the ''RoofStar Guarantee Standards''. Note that a coping flashing may be paired with the reglet flashing, as illustrated. ...ting Deck Structure''']]: Concrete slab shown. Each planter area must have a drain through the roof deck.
    4 KB (513 words) - 18:21, 27 October 2023
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they [[File:MF - Metal Cap Flashing (joints) - A.png|class=img-responsive | link=https://rpm.rcabc.org/images/5/5d/MF_-_Meta
    4 KB (557 words) - 17:40, 13 December 2022
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ;(A) Acceptable Parapet:
    3 KB (397 words) - 14:09, 10 August 2023
  • ...background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive. Nor are they ;(1) Metal Cap Flashing: Cut to form<b> </b>a<b> </b>25mm (1")<b> </b>wide<b> </b>flange for seam fabrication at cap flas
    3 KB (400 words) - 19:08, 22 November 2022
  • ...l is to provide the reader with guidelines for establishing and conducting a roof maintenance program. ;<big>Why Does a Roof Need Maintenance?</big>
    75 KB (11,617 words) - 21:00, 3 September 2021
  • ...implicity and universality. It is simple because all relationships between a unit and its multiples and sub-multiples in the system are in powers of 10. A more detailed treatment of SI and its use are referenced in two National St
    11 KB (1,750 words) - 20:54, 3 September 2021
  • ==A== :The ability of a membrane to resist being worn away by contact with a moving abrasive surface, such as foot traffic, mechanical equipment, wind-b
    76 KB (11,565 words) - 18:09, 26 January 2024
  • A selected list of references used in assembling the<b> RGC <i>Roofing Practi <u>A Decade of Change and Future Trends in Roofing</u>, Proceeding of the <u>198
    4 KB (548 words) - 14:32, 18 August 2023
  • <u>Approval Guide, Factory Mutual Systems, A Guide to Equipment, Material and Services</u>. Norwood, MA: Factory Mutual
    1 KB (184 words) - 20:57, 3 September 2021
  • The following is a list of twelve basic material properties which SPRI's Technical Committee h ;The distance between opposite surfaces of a material. Units of measure are millimetres, mils, or fractions of an inch.
    11 KB (1,753 words) - 15:02, 4 May 2017
  • ...sotactic polypropylene (used for injection molding and extrusion). APP has a lower melting point and is more compatible with asphalt than isotactic poly ...s the use of oil-jacketed kettles, equipped with accurate thermometers and a mechanical agitator to heat the asphalt.
    1 KB (189 words) - 18:41, 4 January 2016
  • In order to formulate materials to satisfy the requirements of a roof membrane, the manufacturer must ensure: ...nes can be complex, but the end product can generally be defined as either a THERMOSET (Section 6.1) or THERMOPLASTIC (Section 6.2).
    3 KB (465 words) - 20:53, 29 September 2016
  • In order to formulate materials to satisfy the requirements of a roof membrane, the manufacturer must ensure: ...nes can be complex, but the end product can generally be defined as either a THERMOSET (Section 6.1) or THERMOPLASTIC (Section 6.2).
    4 KB (470 words) - 20:21, 27 July 2016
  • ...lope roofing (also referred to as &#8220;water shedding roofs&#8221;). For a discussion of the design considerations involved in steep slope roofing see ...ted for use in the RoofStar Guarantee Program and are only manufactured on a limited basis in Canada.
    3 KB (461 words) - 20:36, 27 July 2016
  • ...s during the roll forming process and two-piece floating clips that permit a greater range of thermal movement by allowing differential panel movement t ...lled on curved roof decks, a panel stress calculation must be completed by a professional engineer prior to installation of metal panels.
    4 KB (582 words) - 21:35, 30 October 2017
  • ....3.2.3.-SBS-E.png|class=img-responsive | link=https://rpm.rcabc.org/images/a/ae/10.3.2.3.-SBS-E.png]] :All membranes applied to a vertical surface must be mechanically fastened. Mechanically fastened term
    4 KB (584 words) - 15:27, 26 February 2024
  • :All membranes applied to a vertical surface must be mechanically fastened. 2-component fleece-reinfor ;(A) [[TPO Roof Systems Standard#PART_2|<big>Acceptable Deck</big>]]
    4 KB (599 words) - 22:20, 23 February 2024
  • In order to formulate materials to satisfy the requirements of a roof membrane, the manufacturer must ensure: ...nes can be complex, but the end product can generally be defined as either a THERMOSET (Section 6.1) or THERMOPLASTIC (Section 6.2).
    4 KB (463 words) - 16:20, 20 February 2019
  • ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure ...by trade supplying roof drain. For optional installation methods that use a membrane flashing in place of lead, see the Application requirements under
    3 KB (416 words) - 18:00, 27 October 2023
  • ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure
    3 KB (334 words) - 18:01, 27 October 2023
  • ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure
    3 KB (374 words) - 17:46, 27 October 2023
  • ::Click below for a printable version of this page. ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure
    4 KB (474 words) - 17:59, 27 October 2023
  • ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure
    3 KB (402 words) - 17:50, 27 October 2023
  • (A) TBA
    1 KB (195 words) - 18:45, 27 June 2022
  • ...es]] for application standards and securement. Hemmed edges are required; a kicked-out drip edge is optional but recommended (See [[SBS Roof Systems St ;(A) Acceptable Substrate: Representative
    3 KB (377 words) - 17:55, 27 October 2023
  • :All membranes applied to a vertical surface must be mechanically fastened. Fastener illustrated, toge ;(A) [[EPDM Roof Systems Standard#PART_2|<big>Acceptable Deck</big>]]
    4 KB (580 words) - 16:27, 26 February 2024
  • Image:Part 10 - SBS Expansion Joint (Wall) - A.png | Drawing A ...ane flashing''']]: Waterproofs the expansion joint structure and provides a base layer for the control joint to bond material to bond with.
    2 KB (329 words) - 20:56, 1 November 2022
  • ;(A) '''Wall and cladding''': Generic and representative only.
    3 KB (478 words) - 22:42, 9 December 2022
  • ...Roof Systems Standard#PART_10|'''Membrane Flashing''']]: Carried up walls a minimum 200 mm (8") above roof surface. At window curbs membrane flashing m ...Paver systems are required to have proprietary pedestals that incorporate a minimum 3mm (1/8") gap between adjacent units. See additional requirement
    4 KB (508 words) - 18:51, 27 June 2022
  • ...rane flashing''']]: Waterproofs the expansion joint structure and provides a base layer for the control joint material to bond with. ...]]: Installed as required in Part 10 and applied as the second or third of a two or three-ply membrane system, providing required coverage above the fin
    3 KB (382 words) - 16:29, 12 December 2022
  • Use arrows to scroll through related images (A, B, and C). Click any image to expand. Image:Part 10 - SBS Control Joint (Roof Divider) - A.png | Drawing A
    4 KB (522 words) - 20:57, 1 November 2022
  • ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure
    3 KB (386 words) - 21:52, 16 September 2022
  • [[File:10.3.4.4.jpg | link=http://rpm.rcabc.org/images/a/a0/10.3.4.4.jpg | class=img-responsive]] ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure
    3 KB (360 words) - 18:52, 21 September 2022
  • ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure
    3 KB (377 words) - 18:21, 27 October 2023
  • ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure
    3 KB (344 words) - 18:18, 27 October 2023
  • ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure
    3 KB (381 words) - 18:47, 27 June 2022
  • ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure ;(D) [[SBS Roof Systems Standard#PART_11|'''Metal Flashing''']]: Apply in a bed of mastic. Fastened over membrane to wood blocking or roof deck.
    3 KB (418 words) - 18:15, 27 October 2023
  • ...ms (click on a type to see an illustration). Refer to the table below for a summary of panel manufacturers and the products they supply: ...ed in conformance with '''''RoofStar Guarantee Standards''''', qualify for a five (5) or ten (10) year guarantee under the '''''RoofStar Guarantee Progr
    5 KB (576 words) - 20:33, 26 July 2021
  • ...d in any of the other membrane Standards available in this ''Manual''. As a Part of an entire Standard, it must be read together with all the other Par ...'roof system'' securement requirements matter ('''NOTE''': the video shows a mechanically fastened, conventionally insulated EPDM ''roof system'' constr
    55 KB (7,359 words) - 21:22, 3 October 2023
  • Materials to be covered by the Guarantee Program must be acceptable to RGC. A listing is published in the RCABC Roofing Practices Manual, Section ('''''R Materials to be covered by the Guarantee Program must be acceptable to RGC. A listing is published in the RCABC Roofing Practices Manual, Section C. See
    1 KB (211 words) - 16:09, 6 January 2016
  • ...ndex.php?title=SBS_Roof_Systems_Standard#PART_14 {{hilite | 14 THE ROOF as a PLATFORM: Coverings, Living Spaces and Structures || 2020-July-3 }}]
    3 KB (366 words) - 18:42, 30 August 2021
  • ...dex.php?title=EPDM_Roof_Systems_Standard#PART_14 {{hilite | 14 THE ROOF as a PLATFORM: Coverings, Living Spaces and Structures|| 2021-February-7 }}]
    2 KB (343 words) - 18:18, 31 August 2021
  • ...ndex.php?title=TPO_Roof_Systems_Standard#PART_14 {{hilite | 14 THE ROOF as a PLATFORM: Coverings, Living Spaces and Structures|| 2021-February-7 }} ]
    2 KB (335 words) - 18:43, 30 August 2021
  • ...ndex.php?title=PVC_Roof_Systems_Standard#PART_14 {{hilite | 14 THE ROOF as a PLATFORM: Coverings, Living Spaces and Structures|| 2021-February-7 }} ]
    2 KB (333 words) - 20:29, 30 August 2021
  • ...on with '''''RoofStar Guarantee Standards''''' for the purposes of issuing a '''''RoofStar Guarantee''''' on cedar shake and shingle roofs installed by ...he West Coast Lumber Manufacturers Association, it was agreed to establish a branch of the association to serve those members who manufactured shingles.
    3 KB (358 words) - 15:36, 24 April 2018
  • ...bership list and contact information at [http://www.rcabc.org/members/find-a-member/ '''www.rcabc.org'''] :<big><span style="color:#ff0000">Click the heading for a material type to link to tables displaying all other Accepted Materials in
    2 KB (276 words) - 16:56, 1 February 2023
  • * the insulation may be incompatible with the membrane, resulting in a loss of physical properties
    3 KB (334 words) - 18:08, 16 June 2023
  • ...rds, Guiding Principles and Recommended Practices necessary to qualify for a RoofStar Guarantee. The RPM meets or exceeds the current national and prov ...g remains in effect for 120 days. Consult the '''Technical Updates''' for a list of recent changes to the RPM.
    7 KB (990 words) - 20:54, 2 August 2016
  • Polyurethane foam is the result of a chemical reaction between two liquids, isocyanate and polyols, in combinati ...on steel decks or over a roof that is subject to fire exposure from below, a fire-rated underlayment or thermal barrier (such as gypsum board) should be
    3 KB (444 words) - 17:15, 17 June 2016
  • ...-S701-97 / (CAN / CGSB-51.20-M87) requirements. It is understood that such a certification program requires annual inspections / recertification by an i ...) The expanded beads are stabilized in curing bins, fused into a billet in a block mold, and cut into the desired size, shape and thickness. This proces
    3 KB (422 words) - 17:14, 17 June 2016
  • ...that make a properly milled, graded, and installed cedar shingle or shake a viable and attractive water-shedding roof.
    757 bytes (110 words) - 20:41, 27 July 2016
  • ...terials necessary for the design and installation of a roof qualifying for a RoofStar Guarantee.''' ...ds for the selection and application of materials necessary to qualify for a '''''RoofStar Guarantee''''' are found in this section. Readers are advise
    117 KB (13,071 words) - 18:36, 5 April 2024
  • ...patible polyurethane adhesive. The second board layer must be adhered with a compatible manufacturer's approved polyurethane adhesive. ...ds measuring 12.7 mm (1/2") or more in thickness are acceptable for use in a '''''RoofStar Waterproofing Guarantee'''''. For more on this, see [[RoofSt
    7 KB (968 words) - 20:34, 26 July 2021
  • ...d data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. All materials used under the CERTI-LABEL Program must be manufactured by a Canadian Member Company of the Cedar Shake and Shingle Bureau. Each bundle
    9 KB (1,344 words) - 14:13, 27 July 2021
  • ...adhesive. Must be carried to the outside of the parapet or vertically to a minimum of 200 mm (8”) above the finished roof surface. Welded or adhere ;(A) [[TPO Roof Systems Standard#PART_2|'''Acceptable Deck''']]
    3 KB (439 words) - 21:37, 27 June 2022
  • ...standards as published in the '''RoofStar Roofing Practices Manual''' for a RoofStar 5-Year, RoofStar 10-Year or RoofStar 5-Year Waterproofing guarante
    1 KB (191 words) - 17:16, 22 August 2016
  • ...dards''''' as published in the '''RoofStar Roofing Practices Manual''' for a '''''RoofStar Guarantee''''', unless modified by the contract documents to
    1 KB (181 words) - 18:25, 19 August 2021
  • ...ges/0/0a/A_Failure_of_Imagination_%28Roofing_BC%3B_Vol._19%2C_No._3%29.pdf A Failure of Imagination (Roofing BC, Fall 2022: Vol. 19, No. 3)]</big>
    2 KB (308 words) - 16:36, 16 March 2023
  • :All membranes applied to a vertical surface must be mechanically fastened. Fastener illustrated, toge ;(A) [[SBS Roof Systems Standard#PART_2|<big>Acceptable Deck</big>]]
    4 KB (561 words) - 15:51, 26 February 2024
  • :All membranes applied to a vertical surface must be mechanically fastened. Mechanically fastened term ;(A) [[TPO Roof Systems Standard#PART_2|<big>Acceptable Deck</big>]]
    4 KB (596 words) - 22:32, 23 February 2024
  • <big><big><big><big><big>SBS | Membrane Termination A (Wall) ([[SBS_Roof_Systems_Standard#10.3.2.3._General_Application_Requireme ...lass=img-responsive | link=https://rpm.rcabc.org/images/d/dd/10.3.2.3.-SBS-A.png]]
    6 KB (858 words) - 16:09, 16 February 2024
  • ...characteristics. Reinforcing mats (consisting of polyester, fibreglass, or a combination thereof) are saturated and coated with varied thicknesses of el ...220;Teranap&#8221; series are Siplast&#8217;s major membrane systems, with a number of speciality membranes designed to extend their range of applicatio
    22 KB (3,408 words) - 18:30, 9 November 2016
  • <i>Country of Origin:</i> U.S.A. <i>Country of Manufacture:</i> U.S.A.
    12 KB (1,817 words) - 19:27, 7 November 2016
  • The highest quality raw materials are utilized in a manufacturing process which saturates and coats non-woven glass, composite, ...d data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.<u>RAN
    14 KB (2,024 words) - 18:30, 9 November 2016
  • <i>Country of Manufacture:</i> U.S.A. ...membranes in 1978. Only the highest quality raw materials are utilized in a manufacturing process which impregnates and coats fibreglass or Polyglass r
    8 KB (1,192 words) - 19:52, 7 November 2016
  • The highest quality raw materials are utilized in a manufacturing process which saturates and coats non-woven glass or polyeste ...d data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
    11 KB (1,543 words) - 18:21, 9 November 2016
  • ...and floodcoated with Burmastic adhesive. The system is then finished with a gravel surface. ...d data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
    7 KB (942 words) - 20:12, 7 November 2016
  • ...bership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org] ...utions have been extending the life cycle of buildings like yours for over a century.
    16 KB (2,588 words) - 18:14, 9 November 2016
  • The highest quality raw materials are utilized in a manufacturing process which saturates and coats non-woven glass or polyeste ...data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
    8 KB (1,205 words) - 18:26, 9 November 2016
  • ...rformance modified bitumen. The lower surface is either sanded or receives a poly surface while the top surface is covered with granules or sand. ...d data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
    12 KB (1,673 words) - 19:42, 7 November 2016
  • ...used to saturate and coat non-woven polyester or fibreglass mat to produce a very flexible, high-quality membrane. ...Base sheets are surfaced with sand or thermofusible polypropylene film, or a combination of these. Membranes may be installed either by the torch method
    13 KB (1,969 words) - 19:40, 7 November 2016
  • Country of Origin: U.S.A. ...esign needs of a range of applications. These membranes are available with a variety of surfacing materials including; ceramic granules, polypropylene f
    21 KB (3,147 words) - 19:39, 7 November 2016
  • Country of Origin: Canada of Manufacture: Canada, U.S.A. ...d data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
    19 KB (2,786 words) - 16:54, 4 November 2016
  • THERM 100 is a built-up roofing system utilizing THERMastic, a proprietary elastomeric hot-melt adhesive and waterproofing compound for la ### ULC: Meets Class A requirements.
    20 KB (2,976 words) - 16:55, 4 November 2016
  • This is a Johns Manville Built Up Roofing Specification utilizing Johns Manville Glas ...d data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
    7 KB (992 words) - 16:56, 4 November 2016
  • <i>Country of Origin:</i> U.S.A. <i>Country of Manufacture:</i> U.S.A.
    25 KB (3,685 words) - 16:52, 4 November 2016
  • ...utions have been extending the life cycle of buildings like yours for over a century. ...d data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
    22 KB (3,005 words) - 17:17, 4 November 2016
  • ...n adhesive for fully adhering the TRA Sheet. TRA sheet is formulated from a select composition of polymers, reinforced with scrim. ...d data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
    21 KB (3,244 words) - 22:15, 7 November 2016
  • Country of Origin: U.S.A. Country of Manufacture: U.S.A.
    46 KB (7,081 words) - 22:47, 7 November 2016
  • Country of Origin: U.S.A. Country of Manufacture: U.S.A.
    30 KB (4,433 words) - 22:21, 7 November 2016
  • ...d data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. ...erials, may be used to qualify for a '''''RoofStar Guarantee'''''. To see a list of the manufacturer's products accepted for use in the '''''RoofStar G
    20 KB (3,027 words) - 23:04, 7 November 2016
  • Coutnry of Manufacture: U.S.A. ...ng fuses individual sheets of membrane, creating a monolithic assembly and a consistent, smooth appearance.
    9 KB (1,324 words) - 17:09, 8 November 2016
  • ...ications. Subsequent Ultra-Ply TPO panels are heat welded together to form a continuous sheet. ...d data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
    24 KB (3,556 words) - 22:15, 13 November 2020
  • ...ly membrane systems have been engineered to provide premium performance at a very cost-effective price. Strong, flexible, durable EverGuard&#174; TPO m EverGuard&#174; TSR roof systems utilize either a 0.45", .060", or.080" thick polyester scrim-reinforced thermoplastic polyol
    12 KB (1,686 words) - 17:07, 8 November 2016
  • ...d data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. ...and JM TPO-80 are thermoplastic polyolefin (TPO) membranes reinforced with a polyester fabric, and designed for use in mechanically fastened and adhered
    9 KB (1,238 words) - 17:03, 8 November 2016
  • ...erials, may be used to qualify for a '''''RoofStar Guarantee'''''. To see a list of the manufacturer's products accepted for use in the '''''RoofStar G ...Deck over wood, mechanically fastened. Gypsum board may be required as a thermal barrier between steel deck and combustible insulation (see Build
    30 KB (4,666 words) - 17:04, 8 November 2016
  • Country of Manufacture: Switzerland & U.S.A. ...into a single homogeneous sheet. The sheets are joined on the job site by a hot air welding / fusion process to adjacent sheets or flashings to form an
    42 KB (6,360 words) - 18:54, 9 November 2016
  • Country of Origin: Switzerland of Manufacture: Switzerland &amp; U.S.A. ...into a single homogeneous sheet. The sheets are joined on the job site by a hot air welding / fusion process to adjacent sheets or flashings to form an
    22 KB (3,157 words) - 18:55, 9 November 2016
  • <i>Country of Origin:</i> U.S.A. <i>Country of Manufacture:</i> U.S.A.
    36 KB (5,546 words) - 18:22, 8 November 2016
  • ...und. The non-woven polyester fabric used in ARMOURPLAST membranes provides a highly elastic body with excellent tensile strength. The high percentage of ...mbranes are heat welded to prepared surfaces. The seams are fused, forming a single, continuous watertight membrane.
    18 KB (2,577 words) - 20:02, 8 November 2016
  • ...branes with specific physical properties. Presently, Siplast manufacturers a wide variety of membranes, each designed to satisfy the demands of particul ...data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
    10 KB (1,477 words) - 18:28, 9 November 2016
  • ...f Origin: France of Manufacture: Canada, France, Germany, Switzerland, U.S.A. The highest quality raw materials are utilized in a manufacturing process which saturates and coats non-woven glass, composite,
    7 KB (1,060 words) - 18:29, 9 November 2016
  • ...utions have been extending the life cycle of buildings like yours for over a century. ...d data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
    11 KB (1,769 words) - 18:24, 9 November 2016
  • Intended as a guide for developing office master specifications or preparing specificatio ...aterials and installation for two ply SBS modified bituminous membranes in a protected membrane waterproofing system.
    23 KB (2,972 words) - 19:49, 9 November 2016
  • Intended as a guide for developing office master specifications or preparing project spec ...arantee, copies of Inspection Reports, Membrane Moisture Survey Report and a Maintenance Guide.)
    18 KB (2,262 words) - 19:50, 9 November 2016
  • Intended as a guide for developing office master specifications or preparing specificatio ...Materials and installation for Butyl (IIR) Sheet Membrane waterproofing in a protected membrane (PMR) systems.
    19 KB (2,419 words) - 19:52, 9 November 2016

View (previous 250 | next 250) (20 | 50 | 100 | 250 | 500)